IBM System x iDataPlex dx360 M4 7912 Service Manual page 267

Problem determination
Table of Contents

Advertisement

Automatically notify Support: No
User response: Perform the actions mentioned one at
a time and try the test after each action:
1. Turn off the system and disconnect it from power.
Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest
level.
Date Message Added: 11/12/2013
Reviewed: 11/12/2013
166-824-001 IMM I2C Test Aborted
Explanation: Cannot execute command.
Internal Event: No
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Perform the actions mentioned one at
a time and try the test after each action:
1. Turn off the system and disconnect it from power.
Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest
level.
Date Message Added: 11/12/2013
Reviewed: 11/12/2013
166-901-001 IMM I2C Test Failed
Explanation: IMM Indicates failure in Private bus
(BUS 0).
Internal Event: No
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Perform the actions mentioned one at
a time and try the test after each action:
1. Turn off the system and disconnect it from power.
Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest
level.
3. Run the test again.
4. If failure remains, refer to "Troubleshooting by
symptom" in the system "Installation and Service
Guide" for the next corrective action.
Date Message Added: 11/12/2013
Reviewed: 11/12/2013
166-824-001 • 166-906-001
166-904-001 IMM I2C Test Failed
Explanation: IMM Indicates failure in LED bus (BUS
3).
Internal Event: No
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Perform the actions mentioned one at
a time and try the test after each action:
1. Turn off the system and disconnect it from power.
Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest
level.
3. Run the test again.
4. If failure remains, refer to "Troubleshooting by
symptom" in the system "Installation and Service
Guide" for the next corrective action.
Date Message Added: 11/12/2013
Reviewed: 11/12/2013
166-905-001 IMM I2C Test Failed
Explanation: IMM Indicates failure in Power Supply
bus (BUS 4).
Internal Event: No
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Perform the actions mentioned one at
a time and try the test after each action:
1. Turn off the system and disconnect it from power.
Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest
level.
3. Run the test again.
4. If failure remains, refer to "Troubleshooting by
symptom" in the system "Installation and Service
Guide" for the next corrective action.
Date Message Added: 11/12/2013
Reviewed: 11/12/2013
166-906-001 IMM I2C Test Failed
Explanation: IMM Indicates failure in in PCH bus
(BUS 5).
Internal Event: No
249
Chapter 3. Diagnostics