IBM System x iDataPlex dx360 M4 7912 Service Manual page 132

Problem determination
Table of Contents

Advertisement

806f072b-2201ffff • 806f0813-2581ffff
806f072b-2201ffff
A successful software or
firmware change was detected on
system
[ComputerSystemElementName]. (Bkup
Auto Update)
Explanation: This message is for the use case when
an implementation has detected a Successful Software
or Firmware Change.
Internal Event: No
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0450
SNMP Trap ID:
Automatically notify Support: No
User response: No action; information only. ROM
Recovery :
806f0807-0301ffff
[ProcessorElementName] has
been Disabled. (CPU 1)
Explanation: This message is for the use case when
an implementation has detected a Processor has been
Disabled.
Internal Event: No
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0061
SNMP Trap ID:
Automatically notify Support: No
User response: No action; information only.
806f0807-0302ffff
[ProcessorElementName] has
been Disabled. (CPU 2)
Explanation: This message is for the use case when
an implementation has detected a Processor has been
Disabled.
Internal Event: No
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0061
SNMP Trap ID:
Automatically notify Support: No
User response: No action; information only.
114
System x iDataPlex dx360 M4 Types 7912 and 7913: Problem Determination and Service Guide
806f0807-2584ffff
[ProcessorElementName] has
been Disabled. (All CPUs)
Explanation: This message is for the use case when
an implementation has detected a Processor has been
Disabled.
Internal Event: No
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0061
SNMP Trap ID:
Automatically notify Support: No
User response: No action; information only. One of
the CPUs :
806f0813-2581ffff
A Uncorrectable Bus Error has
occurred on system
[ComputerSystemElementName].
(DIMMs)
Explanation: This message is for the use case when
an implementation has detected a Bus Uncorrectable
Error.
Internal Event: No
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0240
SNMP Trap ID: 50
Automatically notify Support: Yes
User response:
1.
Check the system-event log.
2.
Check the DIMM error LEDs.
3.
Remove the failing DIMM from the system board.
4.
Check for a server firmware update. Important:
Some cluster solutions require specific code levels
or coordinated code updates. If the device is part of
a cluster solution, verify that the latest level of code
is supported for the cluster solution before you
update the code.
5.
Make sure that the installed DIMMs are supported
and configured correctly.
6.
(Trained technician only) Replace the system
board.

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x idataplex dx360 m4 7913

Table of Contents