IBM System x iDataPlex dx360 M4 7912 Service Manual page 216

Problem determination
Table of Contents

Advertisement

218-903-000 • 180-801-000
218-903-000 Brocade:PCILoopbackTest Failed
Explanation: A failure was detected during the
Loopback test.
Internal Event: No
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Rerun the test.
2. Verify whether the firmware is at proper level.
3. Rerun the test.
4. If the problem remains, contact your IBM
technical-support representative.
Date Message Added: 09/03/2012
Reviewed: 09/03/2012
218-904-000 Brocade:ExternalEthLoopbackTest
Failed
Explanation: A failure was detected during the
Loopback test.
Internal Event: No
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Check or replace SFP/cable.
2. Rerun the test.
3. Verify whether the firmware is at proper level.
4. Rerun the test.
5. If the problem remains, contact your IBM
technical-support representative.
Date Message Added: 09/03/2012
Reviewed: 09/03/2012
218-905-000 Brocade:SerdesEthLoopbackTest
Failed
Explanation: A failure was detected during the
Loopback test.
Internal Event: No
Severity: Error
Serviceable: Yes
Recoverable: No
198
System x iDataPlex dx360 M4 Types 7912 and 7913: Problem Determination and Service Guide
Automatically notify Support: No
User response: Complete the following steps:
1. Rerun the test.
2. Verify whether the firmware is at proper level.
3. Rerun the test.
4. If the problem remains, contact your IBM
technical-support representative.
Date Message Added: 09/03/2012
Reviewed: 09/03/2012
218-906-000 Brocade:InternalLoopbackTest Failed
Explanation: A failure was detected during the
Loopback test.
Internal Event: No
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Rerun the test.
2. Verify whether the firmware is at proper level.
3. Rerun the test.
4. If the problem remains, contact your IBM
technical-support representative.
Date Message Added: 09/03/2012
Reviewed: 09/03/2012
180-000-000 Check-point Panel Test Passed
Explanation: Check-point Panel Test Passed.
Internal Event: No
Severity: Event
Serviceable: No
Recoverable: No
Automatically notify Support: No
Date Message Added: 08/29/2012
Reviewed: 08/29/2012
180-801-000 Check-point Panel Test Aborted
Explanation: Check-point Panel Test Aborted. BMC is
unable to verify that the operator information panel
cable is connected.
Internal Event: No
Severity: Warning
Serviceable: Yes

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x idataplex dx360 m4 7913

Table of Contents