IBM System x iDataPlex dx360 M4 7912 Service Manual page 134

Problem determination
Table of Contents

Advertisement

806f090c-2003ffff • 806f090c-2007ffff
Internal Event: No
Severity: Warning
Alert Category: System - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0142
SNMP Trap ID: 22
Automatically notify Support: No
User response:
1.
Reseat the DIMM, and then restart the server.
2.
Replace DIMM n. (n = DIMM number)
806f090c-2003ffff
[PhysicalMemoryElementName]
on Subsystem [MemoryElementName]
Throttled. (DIMM 3)
Explanation: This message is for the use case when
an implementation has detected Memory has been
Throttled.
Internal Event: No
Severity: Warning
Alert Category: System - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0142
SNMP Trap ID: 22
Automatically notify Support: No
User response:
1.
Reseat the DIMM, and then restart the server.
2.
Replace DIMM n. (n = DIMM number)
806f090c-2004ffff
[PhysicalMemoryElementName]
on Subsystem [MemoryElementName]
Throttled. (DIMM 4)
Explanation: This message is for the use case when
an implementation has detected Memory has been
Throttled.
Internal Event: No
Severity: Warning
Alert Category: System - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0142
SNMP Trap ID: 22
Automatically notify Support: No
User response:
1.
Reseat the DIMM, and then restart the server.
2.
Replace DIMM n. (n = DIMM number)
116
System x iDataPlex dx360 M4 Types 7912 and 7913: Problem Determination and Service Guide
806f090c-2005ffff
[PhysicalMemoryElementName]
on Subsystem [MemoryElementName]
Throttled. (DIMM 5)
Explanation: This message is for the use case when
an implementation has detected Memory has been
Throttled.
Internal Event: No
Severity: Warning
Alert Category: System - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0142
SNMP Trap ID: 22
Automatically notify Support: No
User response:
1.
Reseat the DIMM, and then restart the server.
2.
Replace DIMM n. (n = DIMM number)
806f090c-2006ffff
[PhysicalMemoryElementName]
on Subsystem [MemoryElementName]
Throttled. (DIMM 6)
Explanation: This message is for the use case when
an implementation has detected Memory has been
Throttled.
Internal Event: No
Severity: Warning
Alert Category: System - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0142
SNMP Trap ID: 22
Automatically notify Support: No
User response:
1.
Reseat the DIMM, and then restart the server.
2.
Replace DIMM n. (n = DIMM number)
806f090c-2007ffff
[PhysicalMemoryElementName]
on Subsystem [MemoryElementName]
Throttled. (DIMM 7)
Explanation: This message is for the use case when
an implementation has detected Memory has been
Throttled.
Internal Event: No
Severity: Warning
Alert Category: System - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0142

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x idataplex dx360 m4 7913

Table of Contents