To install the 2U chassis in a rack, complete the following steps.
1. If you are installing a new chassis, install the power supply cage and fan
2. If you have the iDataPlex rack:
3. If you have the Enterprise rack:
assembly that you removed from the old chassis (see "Installing a power supply
in a 2U chassis" on page 317 and "Installing the 2U chassis fan assembly" on
page 290).
a. Fasten the captive screw affiliated to the left flange of the chassis to the
rack.
b. On the right side of the chassis, mount the chassis with one M6 screw
which is included in the iDataPlex rack rail kit.
a. Remove the two removable brackets on both sides of the chassis in
advance.
The following illustrations show the locations of the brackets and the screws
on the chassis.
Bracket on the left hand side
Screw
b. Mount the chassis to rack with two M6 screws which are included in the
Enterprise rack rail kit.
Bracket on the right hand side
2U chassis
Bracket
Chapter 5. Removing and replacing server components
2U chassis
Bracket
Screw