81070608-0a01ffff • 810b050a-1e81ffff
Alert Category: Critical - Temperature
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0525
SNMP Trap ID: 0
Automatically notify Support: No
User response: No action; information only.
81070608-0a01ffff
Sensor [SensorElementName]
has deasserted the transition to
non-recoverable. (PS1 12V OC Fault)
Explanation: This message is for the use case when
an implementation has detected that the Sensor
transition to non-recoverable has deasserted.
Internal Event: No
Severity: Info
Alert Category: Critical - Power
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0531
SNMP Trap ID: 4
Automatically notify Support: No
User response: No action; information only. PS1 12V
OV Fault : PS1 12V UV Fault : PS1 12Vaux Fault :
81070608-0a02ffff
Sensor [SensorElementName]
has deasserted the transition to
non-recoverable. (PS2 12V OC Fault)
Explanation: This message is for the use case when
an implementation has detected that the Sensor
transition to non-recoverable has deasserted.
Internal Event: No
Severity: Info
Alert Category: Critical - Power
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0531
SNMP Trap ID: 4
Automatically notify Support: No
User response: No action; information only. PS2 12V
OV Fault : PS2 12V UV Fault : PS2 12Vaux Fault :
810b010a-1e81ffff
Redundancy Lost for
[RedundancySetElementName] has
deasserted. (Cooling Zone)
Explanation: This message is for the use case when
Redundacy Lost has deasserted.
Internal Event: No
134
System x iDataPlex dx360 M4 Types 7912 and 7913: Problem Determination and Service Guide
Severity: Info
Alert Category: Critical - Fan Failure
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0803
SNMP Trap ID: 11
Automatically notify Support: No
User response: No action; information only.
810b010c-2581ffff
Redundancy Lost for
[RedundancySetElementName] has
deasserted. (Backup Memory)
Explanation: This message is for the use case when
Redundacy Lost has deasserted.
Internal Event: No
Severity: Info
Alert Category: Critical - Memory
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0803
SNMP Trap ID: 41
Automatically notify Support: No
User response: No action; information only.
810b030c-2581ffff
Non-redundant:Sufficient
Resources from Redundancy Degraded
or Fully Redundant for
[RedundancySetElementName] has
deasserted. (Backup Memory)
Explanation: This message is for the use case when
a Redundancy Set has transitioned from
Non-redundant:Sufficient Resources.
Internal Event: No
Severity: Info
Alert Category: Warning - Memory
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0807
SNMP Trap ID: 43
Automatically notify Support: No
User response: No action; information only.
810b050a-1e81ffff
Non-redundant:Insufficient
Resources for
[RedundancySetElementName] has
deasserted. (Cooling Zone)
Explanation: This message is for the use case when
a Redundancy Set has transitioned from
Non-redundant:Insufficient Resources.