IBM System x iDataPlex dx360 M4 7912 Service Manual page 54

Problem determination
Table of Contents

Advertisement

4000001e-00000000 • 40000022-00000000
3.
Reinstall the RNDIS or cdc_ether device driver for
the operating system.
4.
Disable the watchdog. Check the integrity of the
installed operating system.
5.
Update the IMM firmware. Important: Some cluster
solutions require specific code levels or coordinated
code updates. If the device is part of a cluster
solution, verify that the latest level of code is
supported for the cluster solution before you update
the code.
4000001e-00000000
Running the backup
Management Controller [arg1] main
application.
Explanation: This message is for the use case where
a Management Controller has resorted to running the
backup main application.
Internal Event: No
Severity: Warning
Alert Category: System - other
Serviceable: No
CIM Information: Prefix: IMM and ID: 0030
SNMP Trap ID: 22
Automatically notify Support: No
User response: Update the IMM firmware. Important:
Some cluster solutions require specific code levels or
coordinated code updates. If the device is part of a
cluster solution, verify that the latest level of code is
supported for the cluster solution before you update the
code.
4000001f-00000000
Please ensure that the
Management Controller [arg1] is
flashed with the correct firmware. The
Management Controller is unable to
match its firmware to the server.
Explanation: This message is for the use case where
a Management Controller firmware version does not
match the server.
Internal Event: No
Severity: Error
Alert Category: System - other
Serviceable: No
CIM Information: Prefix: IMM and ID: 0031
SNMP Trap ID: 22
Automatically notify Support: No
User response: Update the IMM firmware to a version
that the server supports. Important: Some cluster
solutions require specific code levels or coordinated
code updates. If the device is part of a cluster solution,
36
System x iDataPlex dx360 M4 Types 7912 and 7913: Problem Determination and Service Guide
verify that the latest level of code is supported for the
cluster solution before you update the code.
40000020-00000000
Management Controller [arg1]
Reset was caused by restoring default
values.
Explanation: This message is for the use case where
a Management Controller has been reset due to a user
restoring the configuration to default values.
Internal Event: No
Severity: Info
Alert Category: none
Serviceable: No
CIM Information: Prefix: IMM and ID: 0032
SNMP Trap ID:
Automatically notify Support: No
User response: Information only; no action is
required.
40000021-00000000
Management Controller [arg1]
clock has been set from NTP server
[arg2].
Explanation: This message is for the use case where
a Management Controller clock has been set from the
Network Time Protocol server.
Internal Event: No
Severity: Info
Alert Category: none
Serviceable: No
CIM Information: Prefix: IMM and ID: 0033
SNMP Trap ID:
Automatically notify Support: No
User response: Information only; no action is
required.
40000022-00000000
SSL data in the Management
Controller [arg1] configuruation data is
invalid. Clearing configuration data
region and disabling SSL.
Explanation: This message is for the use case where
a Management Controller has detected invalid SSL data
in the configuration data and is clearing the
configuration data region and disabling the SSL.
Internal Event: No
Severity: Error
Alert Category: System - other
Serviceable: No

Advertisement