IBM System x iDataPlex dx360 M4 7912 Service Manual page 239

Problem determination
Table of Contents

Advertisement

User response: Complete the following steps:
1. Perform the actions mentioned one at a time and try
the test after each action.
2. If the problem remains, contact your
technical-service representative.
3. Turn off the system and disconnect it from power.
Wait for 45 seconds. Reseat DIMM(s). Reconnect it
to power.
4. Make sure that DSA and BIOS/uEFI are at the latest
level.
Date Message Added: 09/04/2012
Reviewed: 09/04/2012
201-844-003 Standalone Memory Test Aborted
Explanation: Chipset Error: Problem in masking MSR
machine check control MASK registers.
Internal Event: No
Severity: Warning
Serviceable: No
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Perform the actions mentioned one at a time and try
the test after each action.
2. If the problem remains, contact your
technical-service representative.
3. Turn off the system and disconnect it from power.
Wait for 45 seconds. Reseat DIMM(s). Reconnect it
to power.
4. Make sure that DSA and BIOS/uEFI are at the latest
level.
Date Message Added: 09/04/2012
Reviewed: 09/04/2012
201-845-000 Standalone Memory Test Aborted
Explanation: Chipset Error: Problem clearing MSR
machine check control registers.
Internal Event: No
Severity: Warning
Serviceable: No
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Perform the actions mentioned one at a time and try
the test after each action.
2. If the problem remains, contact your
technical-service representative.
201-844-003 • 201-845-002
3. Turn off the system and disconnect it from power.
Wait for 45 seconds. Reseat DIMM(s). Reconnect it
to power.
4. Make sure that DSA and BIOS/uEFI are at the latest
level.
Date Message Added: 09/04/2012
Reviewed: 09/04/2012
201-845-001 Standalone Memory Test Aborted
Explanation: Chipset Error: Problem clearing MSR
machine check control registers.
Internal Event: No
Severity: Warning
Serviceable: No
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Perform the actions mentioned one at a time and try
the test after each action.
2. If the problem remains, contact your
technical-service representative.
3. Turn off the system and disconnect it from power.
Wait for 45 seconds. Reseat DIMM(s). Reconnect it
to power.
4. Make sure that DSA and BIOS/uEFI are at the latest
level.
Date Message Added: 09/04/2012
Reviewed: 09/04/2012
201-845-002 Standalone Memory Test Aborted
Explanation: Chipset Error: Problem clearing MSR
machine check control registers.
Internal Event: No
Severity: Warning
Serviceable: No
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Perform the actions mentioned one at a time and try
the test after each action.
2. If the problem remains, contact your
technical-service representative.
3. Turn off the system and disconnect it from power.
Wait for 45 seconds. Reseat DIMM(s). Reconnect it
to power.
4. Make sure that DSA and BIOS/uEFI are at the latest
level.
221
Chapter 3. Diagnostics