Internal Event: No
Severity: Warning
Alert Category: Warning - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0490
SNMP Trap ID: 12
Automatically notify Support: No
User response: If the specified sensor is Paddle Card
Temp or Riser 1A Temp, complete the following steps
until the problem is solved:
1.
Make sure that the fans are operating, that there
are no obstructions to the airflow (front and rear of
the server), that the air baffle is in place and
correctly installed, and that the server cover is
installed and completely closed.
2.
Check the ambient temperature. You must be
operating within the specifications (see Server
Features and specifications for more information).
3.
Replace paddle card and riser 1 card.
80010701-1002ffff
Numeric sensor
[NumericSensorElementName] going
high (upper non-critical) has asserted.
(Riser 2A Temp)
Explanation: This message is for the use case when
an implementation has detected an Upper Non-critical
sensor going high has asserted.
Internal Event: No
Severity: Warning
Alert Category: Warning - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0490
SNMP Trap ID: 12
Automatically notify Support: No
User response:
1.
Make sure that the fans are operating, that there
are no obstructions to the airflow (front and rear of
the server), that the air baffle is in place and
correctly installed, and that the server cover is
installed and completely closed.
2.
Check the ambient temperature. You must be
operating within the specifications (see Server
Features and specifications for more information).
3.
Replace riser card.
4.
Replace riser 2 card.
80010701-1002ffff • 80010701-1004ffff
80010701-1003ffff
Numeric sensor
[NumericSensorElementName] going
high (upper non-critical) has asserted.
(Riser 1B Temp)
Explanation: This message is for the use case when
an implementation has detected an Upper Non-critical
sensor going high has asserted.
Internal Event: No
Severity: Warning
Alert Category: Warning - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0490
SNMP Trap ID: 12
Automatically notify Support: No
User response:
1.
Make sure that the fans are operating, that there
are no obstructions to the airflow (front and rear of
the server), that the air baffle is in place and
correctly installed, and that the server cover is
installed and completely closed.
2.
Check the ambient temperature. You must be
operating within the specifications (see Server
Features and specifications for more information).
3.
Replace riser 1 card.
80010701-1004ffff
Numeric sensor
[NumericSensorElementName] going
high (upper non-critical) has asserted.
(Riser 2B Temp)
Explanation: This message is for the use case when
an implementation has detected an Upper Non-critical
sensor going high has asserted.
Internal Event: No
Severity: Warning
Alert Category: Warning - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0490
SNMP Trap ID: 12
Automatically notify Support: No
User response:
1.
Make sure that the fans are operating, that there
are no obstructions to the airflow (front and rear of
the server), that the air baffle is in place and
correctly installed, and that the server cover is
installed and completely closed.
2.
Check the ambient temperature. You must be
operating within the specifications (see Server
Features and specifications for more information).
3.
Replace riser 2 card.
57