Removing a power-supply paddle card from the tray
To remove a power-supply paddle card from the tray, complete the following steps.
System-board tray
1. Read the safety information that begins on page vii and "Installation guidelines"
2. If the tray is installed in a chassis, remove it (see "Removing the system-board
3. Carefully set the tray on a flat, static-protective surface.
4. Remove the system-board tray cover (see "Removing the system-board tray
5. If any simple-swap drives are installed in the tray, complete the following steps:
6. Make a note of where cables are attached to the power-supply paddle card;
7. Remove the four screws that secure the power-supply paddle card to the tray
8. Lift the power-supply paddle card out of the tray.
9. If you are instructed to return the power-supply paddle card, follow all packaging
Power-supply
paddle card
on page 275.
tray from a 2U chassis" on page 279).
cover" on page 280).
a. Note the cable routing of the hard disk drive bracket and cable assembly
cables; then, disconnect the cables.
b. Remove the hard disk drive bracket and cable assembly.
then, disconnect them.
and save them for future use.
instructions, and use any packaging materials for shipping that are supplied to
you.
Chapter 5. Removing and replacing server components