Problem determination
Table of Contents

Advertisement

2.
Update the server firmware on the primary page.
Important: Some cluster solutions require specific
code levels or coordinated code updates. If the
device is part of a cluster solution, verify that the
latest level of code is supported for the cluster
solution before you update the code.
3.
(Trained technician only) Replace the system
board.
806f0113-0301ffff
A bus timeout has occurred on
system
[ComputerSystemElementName]. (CPU
1 PECI)
Explanation: This message is for the use case when
an implementation has detected a Bus Timeout.
Internal Event: No
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0224
SNMP Trap ID: 50
Automatically notify Support: No
User response:
1.
(Trained technician only)Reseat the microprocessor,
and then restart the server.
2.
(Trained technician only)Replace microprocessor n.
(n = microprocessor number)
806f0113-0302ffff
A bus timeout has occurred on
system
[ComputerSystemElementName]. (CPU
2 PECI)
Explanation: This message is for the use case when
an implementation has detected a Bus Timeout.
Internal Event: No
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0224
SNMP Trap ID: 50
Automatically notify Support: No
User response:
1.
(Trained technician only)Reseat the microprocessor,
and then restart the server.
2.
(Trained technician only)Replace microprocessor n.
(n = microprocessor number)
806f0113-0301ffff • 806f0125-0b02ffff
806f0123-2101ffff
Reboot of system
[ComputerSystemElementName]
initiated by [WatchdogElementName].
(IPMI Watchdog)
Explanation: This message is for the use case when
an implementation has detected a Reboot by a
Watchdog occurred.
Internal Event: No
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0370
SNMP Trap ID:
Automatically notify Support: No
User response: No action; information only.
806f0125-0b01ffff
[ManagedElementName]
detected as absent. (PCI Riser 1)
Explanation: This message is for the use case when
an implementation has detected a Managed Element is
Absent.
Internal Event: No
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0392
SNMP Trap ID:
Automatically notify Support: No
User response: Please ensure the PCI riser 1 has
been installed correctly.
806f0125-0b02ffff
[ManagedElementName]
detected as absent. (PCI Riser 2)
Explanation: This message is for the use case when
an implementation has detected a Managed Element is
Absent.
Internal Event: No
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0392
SNMP Trap ID:
Automatically notify Support: No
User response: Please ensure the PCI riser 1 has
been installed correctly.
87