Figure 3-17 Logic Details - And 2 Details; Figure 3-18 Logic Details - Or - Siemens GCP5000 Instruction & Installation Manual

Grade crossing predictor for electrified territory (gce)
Table of Contents

Advertisement

DISPLAY MODULE AND OFFICE CONFIGURATION EDITOR
_________________________________________________________________________________________________________
Use the arrow keys on the Display module to select the AND and press Enter, this will bring up
the logic diagram that shows what terms contribute to the selected AND output as shown in
Figure 3-17. If a component of the AND is negated in the configuration this is shown with the '!'
prefix, so in this case, the NWP is on, so when negated is off, the LED will indicate the state of
!NWP.
Figure 3-17 Logic Details – AND 2 Details
3.1.2.3.3
Logic Details – OR Screen
The Logic Details – OR screen depicts the status of the four ORs (OR 1 – OR 4). Scrolling to
the individual OR and selecting ENTER will open a screen depicting the terms used in the OR.
Figure 3-18 Logic Details – OR
3-13
SIG-00-22-02
JUNE 2022 (Revised September 2022)