Figure 4-15 External Crossing Controller IO Assignment

To sync the lamps on the external controller:
Connect the flash sync output of the GCE to the flash sync I/O of the external
crossing controller as follows:
Connect the FLASH SYNC + output of the GCE chassis to the FLASH SYNC I/O on
the external crossing controller.
Connect the FLASH SYNC - output of the GCE to N of the external crossing
controller. (The power returns for the GCE and the external crossing controller do not
have to be connected.)
When used, connect MAINT CALL of the GCE with MAINT CALL of the external
crossing controller as described in paragraph 6.12.
SSCC IIIi Modules Rev D and later have an isolated flash sync output.
Where battery isolation must be maintained and SSCC IIIi Modules of
Rev C or earlier are used, contact Siemens Technical Support for
application information.
The Aux-1 Lmp Control output de-energizes whenever the lamps on
SSCC-1 flash, either due to activation, gate position, or SSCC health.
If the external controller fails, its gate output will de-energize, causing the
Aux-1 Xng Ctrl Hlth to de-energize and the internal crossing controllers to
activate.
SIG-00-22-02
Version: B.1
SSCC APPLICATIONS & PROGRAMMING GUIDELINES
NOTE
4-33
JUNE 2022 (Revised September 2022)