Siemens GCP5000 Instruction & Installation Manual page 419

Grade crossing predictor for electrified territory (gce)
Table of Contents

Advertisement

Name Input
PSO 'n' TX Code E
PSO 'n' TX Code F
PSO 'n' RX 1 External
PSO 'n' RX 2 External
PSO 'n' External Isl
PSO 'n' Isl Enable
OOS Input 'n' (n = 1..5)
GP 'n'.1 (n=1..2)
GP 'n'.2 (n=1..2)
SIG-00-22-02
Version : B.1
Condition for Input to be Available
PSO 'n' Slot = PSO and
PSO 'n' PSO Module Mode = Rx/Tx and
(PSO 'n' TX Address = Dynamic or
PSO 'n' TX Address = Code E)
PSO 'n' Slot = PSO and
PSO 'n' PSO Module Mode = Rx/Tx and
(PSO 'n' TX Address = Dynamic or
PSO 'n' TX Address = Code F)
PSO 'n' Slot = PSO and
PSO 'n' RX1 Mode = External
PSO 'n' Slot = PSO and
PSO 'n' RX2 Mode = External
PSO 'n' Slot = PSO and
PSO 'n' PSO Module Mode = Crossing
and
PSO 'n' Island Mode = External
PSO 'n' Slot = PSO and
PSO 'n' PSO Module Mode = Crossing
and
PSO 'n' Isl Enable Used = Yes
PSO 'n' Slot = PSO and
OOS Control =Display+OOS IPs
SSCC-'n' Slot = SSCC3i and
SSCC-'n' Number of GPs > 0
SSCC-'n' Slot = SSCC3i and
SSCC-'n' Number of GPs = 2
Found on Menu
PSO Programming /
PSO 'n' /
PSO 'n' Transmitter
PSO Programming /
PSO 'n' /
PSO 'n' Transmitter
PSO Programming /
PSO 'n' /
PSO 'n' Receiver 1
PSO Programming /
PSO 'n' /
PSO 'n' Receiver 2
PSO Programming /
PSO 'n' /
PSO 'n' Island
PSO Programming /
PSO 'n' /
PSO 'n' Island
Basic Configuration/
Adv Preemption
SSCC Programming /
SSCC 'n' Configuration
SSCC Programming /
SSCC 'n' Configuration
9-17
JUNE 2022 (Revised September 2022)
I/O FUNCTIONS AND ASSIGNMENTS
Description
Used to select whether transmitter
sends code E based upon via an
input or internal logic.
Used to select whether transmitter
sends code F based upon via an
input or internal logic.
Used to bring in the state of an
external track circuit if an external
track circuit is used instead of the
internal PSO.
Used to bring in the state of an
external track circuit if an external
track circuit is used instead of the
internal PSO receiver.
Used to bring in the state of an
external island if an external island
track circuit is used instead of the
internal island on the PSO module.
When the island enable input is de-
energized, the island will be treated
as occupied.
When OOS Control =Display+OOS
IPs used in conjunction with the
Display Module to take a PSO
receiver or island out of service.
Used to monitor the Gate Position
input.
Used to monitor a Gate Position
input from a second gate.

Advertisement

Table of Contents
loading