Display Module And Office Configuration Editor; Display Menu Screens; Display Module (A80485) - Siemens GCP5000 Instruction & Installation Manual

Grade crossing predictor for electrified territory (gce)
Table of Contents

Advertisement

_________________________________________________________________________________________________________

DISPLAY MODULE AND OFFICE CONFIGURATION EDITOR

3
DISPLAY MODULE AND OFFICE CONFIGURATION EDITOR
3.1

Display Menu Screens

3.1.1 Display Module (A80485)

The display provides the user interface that allows:
GCP5000 (GCE) configuration:
o Upload a configuration package (PAC) file to the CPU III from the Display's USB drive or
from the Web User Interface (Web U/I).
o Download the configuration package (PAC) file from the CPU III and save it on the
Display's USB drive or to the user's PC via the Web User Interface (Web U/I).
Software Installation, to include the following types of software:
o Master Configuration File (MCF) to the CPU III module.
o Master Executive Files (MEF) to the various cards.
o Non-Vital Executive Files to the Display.
o SEAR IIi software.
Executive
Application – CDL (Control Description Language) files specific to
individual railroads and agencies.
Generate, present, and copy the following reports:
o Configuration (Config) Report
o Version Report
o Program Report
o Minimum Program Report
o Templates Report
o SEAR Incident Reports
Generate, present, and copy the following logs:
o Event Log
o Display Log
o Diagnostic Log
o CPU-Card IO Logs
o Maintenance Log
o Train Log
o SEAR Event Log
o SEAR Application Log
o SEAR CDL Log
SIG-00-22-02
Version: B.1
DISPLAY MODULE AND OFFICE CONFIGURATION EDITOR
SECTION 3
3-1
JUNE 2022 (Revised September 2022)

Advertisement