The PAC file name is created from the combination of the DOT number and date and time, e.g.
CONFIG – {DOT#}-PAC-{date}-{time}.PAC.
The downloaded PAC file will be stored on the USB stick under a folder called:
Safetran\DOT-SITENAME \GCP4000\Configurations
UPLOADING A NEW CONFIGURATION, MEF, OR MCF WILL PLACE
THE GCP IN A RESTRICTIVE STATE AND ACTIVATE THE CROSSING
WARNING SYSTEM.
BEFORE UPLOADING BEGINS, TAKE ADEQUATE PRECAUTIONS TO
WARN ANY PEDESTRIANS, PERSONNEL, TRAINS, AND VEHICLES IN
THE AREA UNTIL PROPER SYSTEM OPERATION IS VERIFIED.
TESTS MUST BE PERFORMED TO VERIFY THE PROPER OPERATION
OF GCP BEFORE PLACING THE SYSTEM BACK IN SERVICE.
TO MINIMIZE THE TIME THAT THE CROSSING IS ACTIVE, IF THE
EXISTING CONFIGURATION NEEDS TO BE SAVED, SAVE IT BEFORE
SELECTING "UPLOAD CONFIGURATION" FROM THE USB WIZARD
MENU.
Due to software commonality issues, the USB Display device utilizes folders
titled GCP 4000 rather than GCP5000.
SIG-00-22-02
Version: B.1

Figure 3-45 PAC File Download Complete

3-33