Table 8-8 PSO Module, A80428-03 User Interface

LEDS
NAME
COLOR
RX1
Red
RX1
Green
RX2
Red
RX2
Green
Island
Red
Island
Green
RX1 (Int)
Red
RX1 (Ext)
Green
RX2 (Int)
Red
RX2 (Ext)
Green
Island (Int)
Red
Island (Ext)
Green
TX Enable
Green
OUT 1
Red
OUT 2
Red
OUT 3
Red
IN 1
Red
IN 2
Red
HEALTH
Yellow
POWER
Green
SIG-00-22-02
Version: B.1
RX1 not calibrated
RX1 is calibrated
RX2 not calibrated
RX2 is calibrated
Island not calibrated
Island is calibrated
On – RX1 Internal track circuit is unoccupied
Off – RX1 Internal track circuit is occupied
Flashing – RX1 Internal track circuit is running its pickup delay
On – RX1 External track circuit is unoccupied
Off – RX1 External track circuit is occupied
Flashing – RX1 External track circuit is running its pickup delay
On – RX2 Internal track circuit is unoccupied
Off – RX2 Internal track circuit is occupied
Flashing – RX2 Internal track circuit is running its pickup delay
On – RX2 External track circuit is unoccupied
Off – RX2 External track circuit is occupied
Flashing – RX2 External track circuit is running its pickup delay
On – Island Internal track circuit is unoccupied
Off – Island Internal track circuit is occupied
Flashing – Island1 Internal track circuit is running its pickup delay
On – Island External track circuit is unoccupied
Off – Island External track circuit is occupied
Flashing – Island External track circuit is running its pickup delay
On – TX is enabled
Off – TX is disabled
On – output energized
Off – output de-energized or failed
On – output energized
Off – output de-energized or failed
On – output energized
Off – output de-energized or failed
On – input energized
Off – input de-energized or failed
On – input energized
Off – input de-energized or failed
Slow (1Hz) – module is healthy and communicating with CPU.
Fast (2Hz) – module is healthy but not communicating with CPU.
Very Fast (4Hz) – module is unhealthy and communicating with CPU.
On steadily when power is applied to the module