Comms Section; Figure 3-2 System View Screen Showing Vcom Icons - Siemens GCP5000 Instruction & Installation Manual

Grade crossing predictor for electrified territory (gce)
Table of Contents

Advertisement

DISPLAY MODULE AND OFFICE CONFIGURATION EDITOR
_________________________________________________________________________________________________________
3.1.2.1.2

Comms Section

This shows the communication status of the SEAR. The icon is not shown if the SEAR IIi is not
used.
Green - SEAR IIi in session
Red
- SEAR IIi out of session
This shows the communication status of the vital comms links. The icons are only shown for the
used vital comms links.
Green – VCOM(x) in session (x=1..4)
Red
- VCOM(x) out of session (x=1..4)

Figure 3-2 System View Screen Showing VCOM Icons