_________________________________________________________________________________________________________
7.5
Surge Protection Requirements
7.5.1 Battery Surge Application Installation
The GCE incorporates built-in surge protection. However, primary surge protection must be
installed on all power supply/battery as shown in Figure 7-17.
. Track wire surge protection is shown on application drawings in Section 2.
WARNING
THE POLARITY OF THESE CIRCUITS MUST BE
OBSERVED, SINCE DAMAGE TO THIS EQUIPMENT
WILL RESULT FROM REVERSED POLARITY.
B1
Customer
Supplied
N1
Battery
Charger
#6
MWS_08-06_BATT_SURGE_4K
04-24-08
SIG-00-22-02
Version: B.1
EARTH GND
B2
PRIME GND
-S
N2
#6
Figure 7-17 Primary Battery Surge Protection
TO OTHER EQUIPMENT
NOTE
MOUNT ITEMS IN
DASHED BOX AS
CLOSE TO BATTERY
AS POSSIBLE
TO OTHER EQUIPMENT
7-21