Siemens GCP5000 Instruction & Installation Manual page 372

Grade crossing predictor for electrified territory (gce)
Table of Contents

Advertisement

DETAILED CASE AND MODULE DESCRIPTION
_________________________________________________________________________________________________________
Diag Display /
Description
DFT
Default Values set
(DIAG3001) /
Operating
parameters have
been set to default.
DFT
Vital Cfg Parms set
to default
(DIAG3002) / Vital
Cfg parameters have
been set to default.
DFT
Configuration set to
default (DIAG3017) /
Configuration set to
default.
INIT
No VLP Comms
(DIAG3020) / The
VLP/CP LED on the
CPU card does not
light
MCF
MCF Checks failed
(DIAG3005) /
Verification of MCF
data failed.
MCF
MCF Compatibility
incorrect
(DIAG3013) / MCF
and MEF are
incompatible
MOD
Module Type Error
(DIAG3006) / The
MEF software is
incompatible with the
module hardware.
SIG-00-22-02
Version: B.1
Cause
New MCF has been loaded
New MCF has been loaded or UCN
changed
The configuration parameters have
been set back to default due to
either:
MCF change
Template change
User setting default
The VLP is rebooting or is in its
Initial State and performing its initial
checks. This may occur after a VLP
reset, or after changing templates.
The MCF is invalid.
The installed MCF is incompatible
with the MEF software
The MEF is incompatible with this
hardware.
Set the operating parameters to the required
values
Set the Vital Cfg parameters to the required
values
Wait. The error will clear itself.
Wait for a minute for the VLP to power up. If
the VLP does not power up, check to see if it
is continuously rebooting by checking the
VLP Health LED.
Obtain and load a valid MCF.
Obtain compatible MCF or MEF software
Reload a valid MEF for this hardware.
8-14
JUNE 2022 (Revised September 2022)
Remedy