Table 8-21 Crossing Controller Connectors - Siemens GCP5000 Instruction & Installation Manual

Grade crossing predictor for electrified territory (gce)
Table of Contents

Advertisement

_________________________________________________________________________________________________________
8.4.4 Crossing Controller Connectors
1 L1
1
L2
B
B
WARNING
IF B OR N ARE FULLY OR PARTIALLY
REMOVED, SIGNALS AND/OR GATES
MAY NOT OPERATE AS INTENDED.
TAKE ALTERNATE MEANS TO WARN
VEHICULAR TRAFFIC AND EMPLOYEES
CAUTION
ASSURE CORRECT POLARITY OR
SEVERE DAMAGE WILL OCCUR
1 BELL
+
1 GC
-
WARNING
DO NOT JUMPER 1 GC-
DIRECTLY TO N ON
CONNECTOR ABOVE
+
IN7.1
-
+
IN7.2
(GD)
-
+
IN7.3
(GP)
-
+
IN7.4
(GD)
-
+
IN7.5
(GP)
-
A80405
SSCC-1
R111804_0846
11-18-04
The number preceding the lamp output connector labels indicates the
SSCC associated with the connector; e.g., 1L1 is associated with
SSCC-1.
The digit preceding the decimal point in input connector labels indicates
the chassis SSCC slot; e.g., IN8.1 is associated with SSCC-2.
SIG-00-22-02
Version: B.1

Table 8-21 Crossing Controller Connectors

CONNECTOR
N
N
SSCC-1
SSCC-2
* See the following Note
DETAILED CASE AND MODULE DESCRIPTION
PINOUT*
1L1
Lamp output 1
1L2
Lamp output 2
B
Battery positive input
B
Battery positive input
N
Battery negative input
N
Battery negative input
1 BELL
Bell output
+
1 GC
Gate output
-
+
IN7.1
Vital crossing input 1
-
+
IN7.2
Vital crossing input 2
(GD)
(gate down input)
-
+
IN7.3
Vital crossing input 3
(gate position input)
(GP)
-
+
IN7.4
Vital crossing input 4
(GD)
(gate down input)
-
+
IN7.5
Vital crossing input 5
(GP)
(gate position input)
-
NOTE
8-41
JUNE 2022 (Revised September 2022)
FUNCTION

Advertisement

Table of Contents
loading

Table of Contents