Table 9-4 System Input Functions - Siemens GCP5000 Instruction & Installation Manual

Grade crossing predictor for electrified territory (gce)
Table of Contents

Advertisement

Name Input
Adv Preempt IP
Preempt Health
Traffic Sys Health
Second Train OP
AND 1 XR Enable
AND 'n' Enable (n= 2..8)
AND 1 XR Wrap
AND 'n' Wrap (n= 2..8)
SIG-00-22-02
Version : B.1

Table 9-4 System Input Functions

Condition for Input to be Available
Preempt Logic = Advance and
Adv Preempt IP Used = Yes
Preempt Logic = Advance and
Preempt Health IP Used = Yes
Preempt Logic = Advance and
Traffic System Health IP Used = Yes
Second Train OP Used = Yes
AND 1 XR Used = Yes and
AND 1 XR Enable Used = Yes
AND 'n' XR Enable Used = Yes
AND 1 XR Used = Yes and
AND 1 XR Wrap Used = Yes
AND 'n' Wrap Used = Yes
Found on Menu
Basic Configuration/
Adv Preemption
Basic Configuration/
Adv Preemption
Basic Configuration/
Adv Preemption
Basic Configuration/
Adv Preemption
Logic Programming/
Logic: PSO ANDing
Logic Programming/
Logic: AND Gates/
Logic: AND 2 .. Logic: AND 8
Logic Programming/
Logic: PSO ANDing
Logic Programming/
Logic: AND Gates/
Logic: AND 2 .. Logic: AND 8
9-15
JUNE 2022 (Revised September 2022)
I/O FUNCTIONS AND ASSIGNMENTS
Description
Used to start advance preemption
from an external source.
Used check the advance
preemption relay is energized when
it is meant to be.
Used monitor health of traffic
system. GCE switches from
Advance preemption to
Simultaneous preemption with
traffic system health input de-
energized.
This is not an external input. It
appears in the list of system inputs
so it can be set to be an equation.
This can then be mapped as a
System Output to a vital output.
Used to de-energize AND 1 XR via
an input or internal logic
Used to de-energize AND 'n' via an
input or internal logic
Used to wrap AND 1 XR via an
input or internal logic.
Used to wrap AND 'n' via an input
or internal logic.