Figure 4-12 SSCC 1 and 2 Configuration Menus

Rmt (Remote) Activation Cancel:
Specifies the maximum length of time that the crossing will remain active when activated
remotely via a command from the SEAR.
Range: 1 – 5 minutes. Default: 2 Min.
Bell On Gate Rising:
When set to Yes, the bell rings while the gates are rising.
Default: No
Mute Bell on Gate Down:
Specifies whether the bell outputs are turned off when all the gate down inputs (GDs) are
energized.
Default: No
4.11.2 Gate Down Inputs
Gate Down inputs (GDs) are used for various applications:
When the GDs are connected to the SSCC inputs, they are monitored by the SEAR
and can be used to generate alarm conditions and monitor crossing operations.
Can be used to control Preemption Gate Down Logic.
Can be used to control Traffic Control Clear Out Interval.
SIG-00-22-02
Version: B.1
SSCC APPLICATIONS & PROGRAMMING GUIDELINES
4-25
JUNE 2022 (Revised September 2022)