1
When other than "QCPU" is selected at SERIES, "NO" cannot be set.
To do so will result in an error.
2
When "QNACPU" is selected at SERIES and "DIFFERENT" is selected at OTHER
STATION, "CCLINK" and "C24" cannot be set. To do so will result in an error.
3
When "QCPUA" or "ACPU" is selected at SERIES
1)
When "SINGLE" is selected at OTHER STATION
"ETHERNET" and "C24" cannot be set. To do so will result in an error.
2)
When "DIFFERENT" is selected at OTHER STATION
"CCLINK" and "C24" cannot be set. To do so will result in an error.
4
When "NET10" or "ETHERNET" is selected at NET1, "NET10" and "ETHERNET"
cannot be set. To do so will result in an error.
5
When "CCLINK" or "C24" is selected at NET1, "CCLINK" and "C24" cannot be set.
To do so will result in an error.
6
When other than "QCPU" is selected at SERIES, "NET10", "ETHERNET" and "C24"
cannot be set. To do so will result in an error.
MELSEC-Q