Thermo Scientific MIRAN 205B Series Instruction Manual page 209

Portable ambient air analyzer
Table of Contents

Advertisement

Compound Name
STYRENE
STYRENE
STYRENE
SULFUR DIOXIDE
SULFUR HEXAFLUORIDE (c)
SULFURYL FLUORIDE
TETRAHYDROFURAN
TOLUENE
TOLUENE
TOLUENE
1.1.2-TRICHLORETHANE
1.1.2.2-TETRACHLOROETHANE
TRICHLOROETHYLENE
TRICHLOROETHYLENE
VINYL ACETATE
VINYL CHLORIDE
VINYL CHLORIDE
VINYLIDENE CHLORIDE
XYLENE
XYLENE
XYLENE
Note: The SapphIRe-SL contains those compounds with and "SL" in the library column. The
SapphIRe-XL contains all compounds in this list.
Accuracy is defined as +/- the average value displayed from five times the detection limit to the
full scale reading (e.g.. Acetaldehyde from 4.0 to 400 ppm: accuracy is +/- 10% of reading.
Detection limit is the point at which the analyzer will consistently and repeatably detect the
presence of the subject gas.
(a) Carbon dioxide (absolute) refers to the measurement of CO
has been purged with CO
of approximately 350 ppm and since the zero gas filter cannot scrub the CO
generate a true level of CO
calibration for CO
calibration, the analyzer must be zeroed with CO
(b) Carbon dioxide (differential) refers to a measurement of CO
zeroed in a level of normal ambient air (350 ppm of CO
background level of CO
(c) 0 to 1 ppm (10%); 1 to 4 ppm (20%)
Library
Acronym
(see key)
STYRNE-H
SL
STYRNE-L
SL
STYRNE-L
SL
SO2
SL
SF6
SL
SULFRYLF
XL
THF
XL
TOLUEN-H
SL
TOLUEN-H
SL
TOLUEN-L
SL
3CLETHAN
XL
4CLETHAN
XL
TCE
SL
TCE
SL
VINLACET
XL
VINLCLOR
SL
VINLCLOR
SL
VINLIDCL
XL
XYLENE-H
SL
XYLENE-H
SL
XYLENE-L
SL
free air such as nitrogen. Since CO
2
is to flush or zero the analyzer with CO
2
was zeroed with nitrogen. Likewise, when using the CO
2
must be added at the zero area to the analyzer's display value.
2
Detection
Detection
HRL
HRL
Limit
Limit
(ppm)
(mg/m3)
(ppm)
(mg/m3) Wavelength Pathlength
1000
4268
15
64.02
200
854
0.6
2.56
200
854
0.7
2.99
30
79
1.2
3.15
4
24
0.01
0.06
30
125
0.1
0.418
500
1478
0.5
1.48
1000
3776
18
67.97
1000
3776
4
15.10
200
755
1
3.78
30
164
0.25
1.37
20
138
0.25
1.72
1000
5384
4
21.54
1000
5384
4
21.54
10
35
0.04
0.14
20
51
0.6
1.545
20
51
1.6
4.10
20
79
0.2
0.79
2000
8702
30
130.53
2000
8702
7
30.46
200
870
1.3
5.66
where the SapphIRe analyzer
2
2
free air.
2
when the SapphIRe analyzer is
2
). When this calibration is used, a
2
H-5
Accuracy
(+/-% of
reading)
11.076
Short
15
11.076
Long
15
12.980
Long
15
8.780
Long
10
10.708
Long
1(10). 4(20)*
11.550
Long
10
8.660
Long
10
13.836
Short
10
9.404
Long
10
13.836
Long
15
13.580
Long
10
12.452
Long
10
10.764
Short
10
11.876
Short
15
8.348
Long
15
10.724
Long
10
9.788
Long
10
12.692
Long
10
13.132
Short
10
12.600
Long
15
13.132
Long
15
is present in the air at levels
, the only way to
2
free air. The factory
2
(absolute)
2