Thermo Scientific Orion 2230XP User Manual

Thermo Scientific Orion 2230XP User Manual

Silica analyzer
Table of Contents

Advertisement

Quick Links

Thermo Scientific Orion
2230XP Silica Analyzer
271539-001
Revision A
March 2016

Advertisement

Table of Contents
loading

Summary of Contents for Thermo Scientific Orion 2230XP

  • Page 1 Thermo Scientific Orion 2230XP Silica Analyzer • • 271539-001 Revision A March 2016...
  • Page 3: Table Of Contents

    Contents Section 1 ........................6 General Information ..................... 6 Safety Precautions ........................6 Symbols Used in this Manual....................... 7 Specifications ..........................7 Section 2 ........................9 Introduction ........................9 Unpacking the Instrument ......................9 Startup Procedure ......................10 General Product Description ...................... 11 User Interface ........................
  • Page 4 Analyzer Hardware Configuration and Calibration ..........34 Optics Calibration ........................34 Optics Calibration Steps ......................35 Reaction Cell Temperature Calibration ..................35 Pumps Calibration ........................36 Pumps Calibration Method ......................36 Analog Outputs Calibration ......................37 Section 6 ........................38 Calibration of the Instrument for Measurement Analysis ........
  • Page 5 Installing Tubing Maintenance Kit ..................67 Cleaning the Reaction Cell ......................69 Preparing the Cleaning solution ..................70 Cleaning the Sample Flow Chamber ..................71 Stand-By Mode and Extended Shutdown .................. 71 SECTION 10......................... 76 Standby and On-Demand Modes ................76 Overview ............................
  • Page 6: Section 1

    S E C T I O N 1 Safety Precautions ™ ™ The Thermo Scientific Orion 2230XP Silica Analyzer has been designed with careful attention to safety. It complies with formal safety design rules established by international regulatory agencies. Observe all safety warnings marked on the instrument.
  • Page 7: Symbols Used In This Manual

    698 mm x 406 mm x 162 mm (27 in x 16 in x 6 in) Weight 16 kg (35 lb) without reagents Mounting Wall or panel mount Measuring Method Heteropoly-molybdenum blue Measuring interval 15, 20, or 30 minutes (selectable settings and user programmable) 2230XP Silica Analyzer Thermo Scientific Orion ...
  • Page 8 50 – 1000 mL/min with < 100 microns particles size (user provides filter) Sample Temperature 5 – 40°C (41 – 104°F) Sample Fitting 6 mm (1/4-in) OD tubing Drain Fitting 9.6 mm (3/8-in) OD tubing  Thermo Scientific Orion 2230XP Silica Analyzer...
  • Page 9: Section 2

    The Orion 2230XP Silica Analyzer uses the colorimetric detection method that relies on specific reagents that are added to the sample to produce a reacted color compound.
  • Page 10: Startup Procedure

    Turn the reagent cap clockwise while holding bottle vertical and level. NOTES: Inspect the tubes to be sure none have been pinched. 4. Prime the tubing. Please repeat the following sequence 3 times. (See Installing the Reagents Section) a. Press Menu.  Thermo Scientific Orion 2230XP Silica Analyzer...
  • Page 11: General Product Description

    General Product Description This User Manual provides the information necessary to obtain the maximum benefits from the Orion 2230XP Silica Analyzer. All operating instructions, functional descriptions, illustrations, and other relevant information are contained in this manual. Descriptions of the system...
  • Page 12: User Interface

    / right or up / down cursor movement. The graphical LCD display shows the date, analysis label, time, navigational menus, information and help to the user, current user, instrument-working mode, current status of the instrument and the soft-key labels.  Thermo Scientific Orion 2230XP Silica Analyzer...
  • Page 13 12. OPERATIONAL KEYS are meant for operation of the instrument. Symbols used   Escape (Cancel/Back) Cursor  Logged out (Locked) Logged in   Scroll Up Scroll Down Print Delete    Scroll Left Scroll right   Accept Reject 2230XP Silica Analyzer Thermo Scientific Orion ...
  • Page 14: Menus Display

    In AUTO mode, the user can navigate between different menus even NOTE: though the instrument is performing a measurement or a calibration. POWER AND I/O SIGNALS CONNECTIONS REACTION CELL Figure 1: Orion 2230XP Silica AIR VENT Analyzer SiO layout RGT2 SAMPLE & REAGENT 2 PUMP...
  • Page 15: Analysis Reaction Principle

    All of the reagents and standard vent tubes need to exhaust to the outside of the enclosure, to minimize the trapping of any vapors inside the enclosure. 2230XP Silica Analyzer Thermo Scientific Orion ...
  • Page 16: Reagent Consumption

    The Silica analysis requires three reagents. The reagent usage depends on the frequency of analysis. Typically 0.20 mL of each reagent is used per analysis cycle. Based on 4 analyses per hour, the 1 Liter reagents should last approximately 45 days.  Thermo Scientific Orion 2230XP Silica Analyzer...
  • Page 17: Section 3

    NEMA 12 and the Fluidics enclosure is a NEMA 4X fiberglass with a clear door window. The Orion 2230XP Silica Analyzer should be installed in a well-ventilated location, with ambient temperature between 5°C and 45°C (41° to 113°F); and relative humidity not to exceed 90% at 40°C.
  • Page 18                                 SAMPLE RETURN 1/4 '' DRAIN 3/8 '' SAMPLE IN 1/4 '' 41mm (1.62 ") 132mm (5.19 ") 25mm (0.98 ") 30mm (1.18 ") VENT LINES  Thermo Scientific Orion 2230XP Silica Analyzer...
  • Page 19: Plumbing Connections

    OD (6 mm OD) flexible tubing. The drain fitting at the bottom of the analyzer requires ⅜ -in OD (9.6 mm OD) flexible tubing. The air purge inlets require ¼-in OD tubing. The air purge supply must be filtered externally and free of oil and any other particulates. 2230XP Silica Analyzer Thermo Scientific Orion ...
  • Page 20: Installing Peristaltic Pump Head Tubing

    Lubricate the tubing with a pea-sized quantity of silicone oil. Fit the new tube and replace in the pressure plate. Note that the pressure plate sides must click properly in the pump head assembly and align on both sides.  Thermo Scientific Orion 2230XP Silica Analyzer...
  • Page 21 You can test the pump under Diagnostics menu for proper operation: MENU ➔ SERVICES ➔ DIAGNOSTICS ➔ PUMPS, VALVES & STIRRER Figure 5: Installing peristaltic pump head tubing - (Dual channel) Figure 6: Installing peristaltic pump head tubing - (Single channel) 2230XP Silica Analyzer Thermo Scientific Orion ...
  • Page 22: Installing The Reagents

    See Figure 7. When using line cords, use only certified power cords of 3 core, min 0.75 mm / 18AWG, min. temperature of 75°C, H05VV-F. The power safety ground must be provided for proper operation.  Thermo Scientific Orion 2230XP Silica Analyzer...
  • Page 23 Table 1: AC power terminal wire connections HOT or L ( Line) black brown Protective Earth Ground (PG) green green with yellow tracer Neutral (n) white blue Figure 8: AC power connections AC POWER CONNECTIONS 2230XP Silica Analyzer Thermo Scientific Orion ...
  • Page 24: Analog Outputs Connections

    Strip the insulation on each wire back ¼-in.  Insert the wire ends through the uppermost opening below the terminal screw and make sure that the stripped wire ends are in the terminal, tighten the connector screws.  Thermo Scientific Orion 2230XP Silica Analyzer...
  • Page 25  RELAY contacts are rated at: 250V, 2A AC 500W (non-inductive load).  All inputs (except IN 6 & 7) must be connected to POTENTIAL FREE contacts. Ethernet Figure 10: Communication ports RS-232 2230XP Silica Analyzer Thermo Scientific Orion ...
  • Page 26 Normally open contact relay 2 Common contact relay 2 Normally closed contact relay 3 Normally open contact relay 3 Common contact relay 3 Normally closed contact relay 4 Normally open contact relay 4 Common contact relay 4  Thermo Scientific Orion 2230XP Silica Analyzer...
  • Page 27: Inputs Signal Connections

    The analyzer has two communication connectors located at the right side in the upper cabinet. See Figure 12. For connecting to them, use the communication conduit hub port on the right side of the instrument for wire entry. 2230XP Silica Analyzer Thermo Scientific Orion ...
  • Page 28: Section 4

    Startup and Operation S E C T I O N 4 Each Orion 2230XP Silica Analyzer gets thoroughly wet-tested and calibrated at the factory, so the system is ready to begin analyzing sample streams. The results of this activity are recorded in a Quality Control Report shipped to you with the analyzer.
  • Page 29: Executing A Manual Calibration

    Analyzer will continue to use the previously stored calibration and will flash the “CHK CAL” message in the Info section of the LCD screen. The “CHK CAL” message can be cleared by resetting the fault alarm under: 2230XP Silica Analyzer Thermo Scientific Orion ...
  • Page 30: Placing The Analyzer Into Service

    STOP key. If the STOP key is pressed before a measurement cycle is complete, it is highly recommended to perform both the AUTO PRIME ALL and CLEAN sequences described in Section 4.  Thermo Scientific Orion 2230XP Silica Analyzer...
  • Page 31: Running An Analysis (Analyze Once)

    RS-232 port. The validation cycle can be executed on any available solution standard or sample selected by the user in the validation setup parameters menu. 2230XP Silica Analyzer Thermo Scientific Orion ...
  • Page 32: Calibration

    Priming fills the tubing, purges the lines of air, and prepares the analyzer for measurement mode. The PRIME VOLUME in mL applies to all the listed solutions in the priming menu.  Thermo Scientific Orion 2230XP Silica Analyzer...
  • Page 33 User may select to pull back all or any one of the reagents or standard. 2230XP Silica Analyzer Thermo Scientific Orion ...
  • Page 34: Section 5

    Pumps and Analog Outputs. Optics Calibration Orion 2230XP Silica Analyzer optics consists of a NIR LED light path and a photo-detector. The analyzer is capable of driving three LED and the intensity of each of the LED can be individually varied.
  • Page 35: Optics Calibration Steps

    In order to get consistent and repeatable measurements, the method is setup such that the reaction cell in the Orion 2230XP Silica Analyzer is heated to a specific set point (25°C). A heater element located on the back plate of the reaction cell controls the temperature. The temperature of the reaction cell is measured by a thermistor embedded in the reaction cell body.
  • Page 36: Pumps Calibration

    MENU ➔ SERVICE ➔ HARDWARE SETUP ➔ EDIT CALIBRATED VALUES Pumps Calibration The Orion 2230XP Silica Analyzer uses peristaltic pumps to move fluids through the reaction cell. The pump tubing will require replacement periodically. Please refer to Chapter 9 for details.
  • Page 37: Analog Outputs Calibration

    MENU ➔ SERVICES ➔ DIAGNOSTICS ➔ ANALOG OUTPUT ➔ CHANNEL –1: By pressing ENTER the user may select the signal level from the following settings: 0, 4, 10, 12, and 20 mA 2230XP Silica Analyzer Thermo Scientific Orion ...
  • Page 38: Section 6

    S E C T I O N 6 Measurement Analysis In the Analysis mode, the Orion 2230XP Silica Analyzer measures the absorbance of light through the sample, and compares the result with the absorbance of light through a standard solution of known concentration.
  • Page 39: Methods Of Calibration

    The Measured Absorbance is the result absorbance after subtracting the Blank Absorbance. Methods of Calibration Two methods of calibration are provided in the Orion 2230XP Silica Analyzer. SINGLE POINT calibration uses high concentration standard alone, and BASE LINE calibration uses either very low or zero standards.
  • Page 40: High Range Dilution-Factor Calibration

    DILUTION PARAMETERS Consult the factory before modifying the default dilution steps. Press (+) to access the dilution steps. The automatic dilution cycle may be turned off using either a higher than expected AU limit:  Thermo Scientific Orion 2230XP Silica Analyzer...
  • Page 41: Theory Of Measurement

    Theory of Measurement Measurement in the Orion 2230XP Silica Analyzer is done by measuring the absorbance of a single wavelength of light through the sample, and comparing the result with the absorbance of the same wavelength of light through a standard solution of known concentration.
  • Page 42: Mode Of Measurement

    Calibration of the Instrument for Measurement Analysis Mode of Measurement The Orion 2230XP Silica Analyzer is designed to provide on-line process measurements, and has two modes of operation. The mode is always displayed at the bottom right, i.e., below the Info field and above the status field of the display.
  • Page 43: Manual Restart Mode

    Even though the instrument is running continuously and displays RUN MODE, to know the actual RESTART mode of the instrument from MAIN NOTE: MENU follow the sequence: MENU ➔ SETUP ➔ (+) ANALYSIS PARAMETERS ➔ MODE 2230XP Silica Analyzer Thermo Scientific Orion ...
  • Page 44: Measurement Cycle

     Section 6 Calibration of the Instrument for Measurement Analysis Measurement Cycle The Orion 2230XP Silica Analyzer follows a sequence of steps or events for performing the analysis cycle. They are: 1. Cell Wash 2. Sample Capture 3. Optics Testing 4.
  • Page 45: Checking Reaction Temperature

    If it does not reach stability or set point in the allowed time, it will flag a warning message and proceed to the next step. The info field (if enabled) shows the temperature progress bar. 2230XP Silica Analyzer Thermo Scientific Orion ...
  • Page 46: Blank Measurement

    After pumping the reagent, the stirrer is turned on for an editable period of time called STIR TIME to mix the reagent thoroughly with sample.  Thermo Scientific Orion 2230XP Silica Analyzer...
  • Page 47: Collect Data

    ANALYSIS PARAMETERS for the POST WASH EVENT. To set the post wash parameters from the MAIN MENU follow the sequence: MAIN MENU ➔ SETUP ➔ ANALYSIS PARAMETERS ➔ (+) POST WASH EVENT ➔ POST WASH CYCLES 2230XP Silica Analyzer Thermo Scientific Orion ...
  • Page 48: Measurement Data

    Calibration of the Instrument for Measurement Analysis Measurement Data The Orion 2230XP Silica Analyzer product stores measurement and calibration results for up to 31 days. The data for each sample analysis cycle or calibration may be retrieved under REVIEW RESULTS menu screen with the corresponding time stamp and other related operating parameters.
  • Page 49: Section 7

    Services - For system administration, hardware setup, prime fluidics and diagnostics; and control of the various devices including LED, pumps, valves, input level sensors, relays and analog outputs. Press the STOP key to exit Auto RUN mode to access the Service Menu. NOTE: 2230XP Silica Analyzer Thermo Scientific Orion ...
  • Page 50: Setup Menu

    All post wash cycles can be turned OFF when set to the “NOT ASSIGNED”. Cleaner Parameters Menu Allows configuration of the parameters for manual or periodic cleaning of the reaction cell.  Thermo Scientific Orion 2230XP Silica Analyzer...
  • Page 51: Measurement Menu

    Allows manual calibration to be performed using standard solutions. The slope and intercept values obtained here may be edited in the CALIBRATION PARAMETERS menu. When performing a manual calibration, the user is restricted from navigating through other menus. 2230XP Silica Analyzer Thermo Scientific Orion ...
  • Page 52: View Data And Alarms Menu

    Zoom works as (X hrs displayed)/4, around the cursor position. Un-zoom is the exact opposite of zoom. Delete All Calibration Results Allows the user to delete the entire calibration database after confirmation. Delete All Analysis Results Allows the user to delete the entire analysis database after confirmation.  Thermo Scientific Orion 2230XP Silica Analyzer...
  • Page 53: Service Menu

    Delete User Menu Allows technician to delete a user from the users list. Add User Menu Allows technician to add a new user to the user’s list. Up to six different users may be added. 2230XP Silica Analyzer Thermo Scientific Orion ...
  • Page 54: Hardware Setup Menu

    Allows technician to calibrate the flow rate of the pumps. Calibrate Optics Allows technician to calibrate the optics. Calibrate Analog Outputs Allows technician to calibrate the two analog outputs. Edit Calibrated Values Allows technician to edit the calibrated results for fine-tuning.  Thermo Scientific Orion 2230XP Silica Analyzer...
  • Page 55: Prime Fluidics Menu And New Reagents Blank

    1 second. A new command received supersedes the previous command; in essence it will interrupt the previous command to execute the new command.  Analyze once  RUN/STOP  Calibrate  Validate (the source is defined in the validation menu)  Not assigned 2230XP Silica Analyzer Thermo Scientific Orion ...
  • Page 56: Default And Lost Or Forgotten Passwords

    User 6 - 666666 (6 sixes) If a user password is forgotten, the technician can delete the user and then add the user back. If the technician password is forgotten, call customer support: 1.800.225.1480.  Thermo Scientific Orion 2230XP Silica Analyzer...
  • Page 57: User Interface Tree

    (+) Press + sign to go to next page Analysis Parameters Validation Parameters Cleaner Parameters Calibration Parameters Method (+) Page 3 Date & Time Daylight Saving Recovery After Power Failure Ethernet Parameters RS232 Parameters Language 2230XP Silica Analyzer Thermo Scientific Orion ...
  • Page 58 Prime Sample Priming Volume (+/-) Press (+) to go to page 2 New Reagents Blank Diagnostics Pumps, Valves and Stirrer Inputs Status Relays Analog Outputs LED & Detector Control ** Consult Factory first  Thermo Scientific Orion 2230XP Silica Analyzer...
  • Page 59 Reaction Cell Temperature Wavelength Blank Measurement (+) Page 2 Reagent 1-3 and Stir Time (+) Page 3 (+) Press + sign to go to next page Cell Wash Flow rate Reagent 1-3 flow rate 2230XP Silica Analyzer Thermo Scientific Orion ...
  • Page 60: Section 8

    Validate, Not assigned DISPLAY PARAMETERS Contrast To adjust the display contrast. 120 to 200 Screen saver time duration for Back Light On-Time 0 to 255 minutes, 0 for Continuously On backlight of display. 2230XP Silica Analyzer Thermo Scientific Orion ...
  • Page 61 Depends on the inner diameter of the The rate at which the sample Cell Wash Flow Rate pump tubing. It is derived from the is pumped to wash the cell. calibration of pumps. 2230XP Silica Analyzer Thermo Scientific Orion ...
  • Page 62 NIR3 810 nm Allows the blank measurement Disable, Before Reagent1, Reagent2, Blank Measurement in the analysis cycle. Before Reagent3 The amount of reagent pumped Reagent Volume 0 to 6.00 mL in to the cell.  Thermo Scientific Orion 2230XP Silica Analyzer...
  • Page 63 PC for the selected data range. The time interval in which the Last 12 hr, 1 Day, 2 Days, 3 Days, Data Range analysis results are to be retrieved. 1 Week, 2 Weeks, 3 weeks and All 2230XP Silica Analyzer Thermo Scientific Orion ...
  • Page 64 Prints all the system parameters. None Configuration Print Analysis Prints only the analysis parameters. None Parameters Print Method Parameters Prints only the method parameters. None Print Clean Parameters Prints only the clean parameters. None  Thermo Scientific Orion 2230XP Silica Analyzer...
  • Page 65 LED & ADC Select LED To test the functionality of LED. NIRx 810, None Intensity Intensity of the LED. 0% to 100% Optics Amplifier Gain Changing the gain of the amplifier. 0 to 255 2230XP Silica Analyzer Thermo Scientific Orion ...
  • Page 66: Section 9

    SERVICES ➔ PRIME FLUIDICS ➔ AUTO PRIME Repeat AUTO PRIME if you notice air bubbles in the tubing. Each reagents kit comes with a REAGENT BLANK value. After changing the reagent you must enter the new value. 2230XP Silica Analyzer Thermo Scientific Orion ...
  • Page 67: Installing Tubing Maintenance Kit

    Replace the pump tubing as described in Plumbing Connections Section. Replace with identical tubing from the maintenance kit by reversing the procedure. Apply silicone lubricant (supplied with the kit) to the pump rollers before re-installing the tubing. 2230XP Silica Analyzer Thermo Scientific Orion ...
  • Page 68 Reagents 1, 2 and 3 Pumps PUMP (larger tubing OD) (smaller tubing OD, all the same) Figure 14: Maintenance kit assembly detail Always use 2 drops of Silicone Oil on the platen before replacing on pump  Thermo Scientific Orion 2230XP Silica Analyzer...
  • Page 69: Cleaning The Reaction Cell

    ½ hour. You may repeat the cleaning procedure as needed. The reaction cell assembly can swing down to allow better access. Undo both NOTE: thumb screws and swing down. 2230XP Silica Analyzer Thermo Scientific Orion ...
  • Page 70: Preparing The Cleaning Solution

    2. Add to the solution 5 g analytical grade di-sodium EDTA and stir to dissolve. 3. Transfer the solution to a 1 liter measuring cylinder and make to the mark with more high purity water. Mix well and store in a tightly sealed plastic bottle.  Thermo Scientific Orion 2230XP Silica Analyzer...
  • Page 71: Cleaning The Sample Flow Chamber

    To put the System in Stand-by mode, make sure to press the STOP key and check the DISPLAY field next to F4 to show MANUAL RESTART. If AUTO RESTART is selected, you need to set the mode to Manual: MENU ➔ SETUP ➔ + ANALYSIS PARAMETERS ➔ MODE 2230XP Silica Analyzer Thermo Scientific Orion ...
  • Page 72 User is trying to delete all calibration Are you sure you want to None. Deleted records are not records. (At least one calibration delete all calibration results? recoverable. record is available in the database.)  Thermo Scientific Orion 2230XP Silica Analyzer...
  • Page 73 Run a Clean Cycle and try again. Inspect cell and clean, check for Testing optics, please check No light output from optics. light detection under LED & for optics failure DETECTOR CONTROL in Diagnostics menu. 2230XP Silica Analyzer Thermo Scientific Orion ...
  • Page 74 Temperature above set point May be due to the connectors or the Check for thermistor and heater please check for hardware thermistor or heater malfunctioning. connections, and calibrate them. malfunction.  Thermo Scientific Orion 2230XP Silica Analyzer...
  • Page 75 Reagent Bottle Cap - includes fittings 2230SC Standard Bottle Cap - includes fittings Reagents and Standards 2230RE Reagents 223020 200 ppb Calibration Standard 223002 20 ppb Calibration Standard 223010 100 ppb Calibration Standard 223030 1000 ppb Calibration Standard 2230XP Silica Analyzer Thermo Scientific Orion ...
  • Page 76: Section 10

    This shift has caused a need for analyzers to work from a continuous mode to an on-demand mode. Thermo Scientific identified this requirement as an enhancement feature and has introduced this into the new Orion 2230 Silica Analyzer.
  • Page 77 SAMPLE: The system will use sample only. In case of NO sample (sample loss) or sensor not assigned the daily priming and flush of the cell is NOT executed. The system will force a PRIME ALL sequence when analysis is resumed. 2230 Silica Analyzer Thermo Scientific Orion ...
  • Page 78: Factory Setup Recommendations When Operating In "On-Demand" Mode

    ON (closed contact) and stop analysis (STOP) with switch in the OFF position. When stopped, the unit will switch automatically to stand-by after one hour. In stand-by mode, the system will execute the necessary house-keeping to maintain a ready state.  Thermo Scientific Orion 2230 Silica Analyzer...
  • Page 79: Section 11

    This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. The Thermo Scientific Orion 2230XP Silica analyzer is CE and cTUVus certified, which includes testing to EMC and US and Canadian standards.
  • Page 80: Declaration Of Conformity

    Declaration of Conformity Manufacturer: Thermo Fisher Scientific, Inc. 22 Alpha Road Chelmsford, MA 01824 USA The manufacturer hereby declares that the Orion 2230XP Silica analyzer conforms with the following standards and documents: Safety 2006/95/EC Low Voltage Directive EN/IEC 61010 -1:2010...
  • Page 81: Warranty Information

    AND ALL OTHER WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE, EXCEPT TITLE, ARE HEREBY OVERRIDDEN AND EXCLUDED. NO LIABILITY SHALL ATTACH TO THERMO SCIENTIFIC EITHER IN CONTRACT OR IN TORT, FOR ANY PERSONAL INJURY, DEATH, DAMAGE TO PROPERTY, LOSS OF PROFITS, DAMAGES,...
  • Page 82: Warranty Shipments/ Returns/Adjustments

    Use only Thermo Fisher Scientific products or Thermo Fisher Scientific- approved products in your Thermo Scientific Analyzer. Thermo Fisher Scientific shall not be liable for damage to or malfunction of the system, which it deems was caused by the use of unauthorized materials.
  • Page 83 thermoscientific.com/processwater © 2014 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific and its subsidiaries. Water Analysis Instruments North America Netherlands India Japan Toll Free: 1-800-225-1480 Tel: (31) 020-4936270 Tel: (91) 22-4157-8800 Tel: (81) 045-453-9175 info.water.uk@thermo.com wai.asia@thermofisher.com wai.asia@thermofisher.com...

Table of Contents