Manuals and User Guides for Thermo Scientific ESCALAB 250. We have
1
Thermo Scientific ESCALAB 250 manual available for free PDF download: Manual
Thermo Scientific ESCALAB 250 Manual (15 pages)
Monochromated X-Ray Source with XR5 Electron Gun
Brand:
Thermo Scientific
| Category:
Measuring Instruments
| Size: 0 MB
Table of Contents
Table of Contents
1
Figures
2
Health and Safety
3
Safety Warnings: ESSENTIAL READING
3
Safety Interlocks
3
Figure 2-1: X-Ray Sofware Interlocks
3
Figure 2-2: Rear View of the T352/NT Showing the Interlock Leds
3
Description
4
Introduction
4
Figure 3-1: the Monochromator Assembly
4
XR5 Electrostatic Electron Gun
5
Cathode
5
Anode
5
Water Cooling Circuit
5
Monochromator Crystal Assembly
5
Figure 3-2: Major Features of the XR5 Electron Gun
5
Figure 3.3: the Monochromator Crystal Manipulator
5
Moving the XR5 Anode
6
Monochromator Fine Tuning
6
Alignment of the Analysis Centre and Microscope Cross Hairs
6
Figure 3-4: a Schematic of Bragg X-Ray Diffraction
6
Figure 3.5: Leg Angle Adjustment
6
T352/NT Computer-Controlled Power Supply
7
Figure 3-6: Adjustment of the Crystal Manipulators
7
Monochromator Operation
8
Avantage Data System Monochromator Controls
8
Errors and Warnings
8
Different XR5 Operating Modes
8
Figure 4-1: Avantage Properties Book
8
Figure 4-2: Control Properties Book
8
Figure 4-3: Water Flow Fail Light Within the Trips
8
Switching on the Re-Circulated Water
9
Observing the Monochromator Spot
9
Figure 4-4: Observing the Monochromator Spot Size on a Phosphor Sample
9
Figure 4-5: Anode Operation Limits for the XR5 Mono. X-Ray Source
9
Maintenance
10
Degassing - after a System Vent and Bake
10
Re-Alignment after a Bake
10
Figure 5-1: Crystal Manipulator Viewed from Behind the System
10
Anode Maintenance
11
Replacing Anodes
11
Figure 5-2: Location of the Anode Shift Drive
11
Figure 5-3: XR5 Anode Assembly
11
Replacing Filaments/Cathodes
12
Figure 5-4: XR5 Anode Orientation
12
Figure 5-5: XR5 Lens and Emitter Assemblies
12
Figure 5-6: XR5 Emitter Flange Assembly
12
Figure 5-7: XR5 Emitter Cup Assembly
13
Figure 5-8: XR5 Lens Assembly
13
Anode Cap Cleaning
14
Ceramic Replacement
14
Crystal Maintenance
14
Fault Finding
14
Index
15
Advertisement
Advertisement
Related Products
Thermo Scientific Orion 2120XP
Thermo Scientific 20-52-NM
Thermo Scientific 20-59-NM
Thermo Scientific Partisol 2000i
Thermo Scientific Partisol 2000i-D
Thermo Scientific MIRAN 205B Series
Thermo Scientific 2210AM
Thermo Scientific Orion 2230XP
Thermo Scientific 20-55-NM-P
Thermo Scientific 20-35-NM-DIN
Thermo Scientific Categories
Laboratory Equipment
Measuring Instruments
Freezer
Accessories
Refrigerator
More Thermo Scientific Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL