Connecting A40Dx Auger Electrical And Hydraulics - MacDon M1 Series Unloading And Assembly Instructions

Windrowers
Table of Contents

Advertisement

25. Press rotary scroll knob (A) on the HPT to highlight the
QuickMenu options.
26. Rotate scroll knob (A) to highlight HEADER FLOAT
symbol (B). Press the scroll knob to select it.
27. Turn scroll knob (A) to highlight left (B) or right (C) float and
press knob (A) to activate the selection.
28. Rotate scroll knob (A) to adjust the float setting and press
the knob to make your selection.
IMPORTANT:
Float adjustments of 1.0 (out of 10) change the header
weight at the cutterbar by approximately 91 kg (200 lb.).
Adjust the float in increments of 0.05 to fine-tune the float
setting.
29. Shut down the engine, and remove the key from
the ignition.
30. Grasp one end of the auger header and lift it. The lifting
force used should be 357 N (80 lbf.) at both ends of the
auger.

5.1.2 Connecting A40DX Auger Electrical and Hydraulics

Connecting the A40DX electrical and hydraulic connections to the windrower is a simple procedure, thanks to the
multicoupler. There is an additional step to perform if you are swapping a rotary disc header for an auger header.
CAUTION
Do NOT stand on an unlocked platform. It is unstable and may cause you to fall.
215620
ATTACHING A HEADER TO THE WINDROWER
136
Figure 5.15: HPT Display
Figure 5.16: HPT Display
Revision A

Advertisement

Table of Contents
loading

This manual is also suitable for:

M1170M1240

Table of Contents