4 Troubleshooting

4.1 Overview of troubleshooting

The LD6 uses a touch screen to access an embedded Windows XP operating system.
The system contains no user-serviceable parts.
The cover should not be removed except under the guidance of a VERIPOS engineer,
first ensuring that the unit is isolated from all AC and DC power supplies.
Problems experienced when using the LD6 system relate to antenna connectivity,
correction signal reception, configuration errors or relate to the GNSS satellite positioning
signal reception for inclusion in calculating a position solution.
4.1.1

Hardware

Hardware fault finding should be limited to checking the security of connectors and
checking supply voltage.
It is strongly recommended before detailed investigation is undertaken to first check
coaxial cable integrity and correct location of antennas.
This manual provides some guidance for troubleshooting the LD6 IMU.
4.1.2

Power faults

Fault
Screen blank
LD6 (Version 8 & Version 50) Operations Manual
Reason
Shutdown has been
activated from Action menu
but the power switch in on
External supply fault,
disconnected or switched
off
Fault in AC/DC supply.
LD6 fault.
Remedy
Toggle the power switch. This will reboot the unit
and the MMI should appear.
Check power to the LD6. Adjust screen
brightness using the control on the left side of the
LD6.
Check power connections to the unit for physical
and electrical integrity.
Disconnect the power supply. Check voltages
to and from unit. The LD6 AC is 110/240 V. DC
power 12–24 VDC.
Reconnect power and allow LD6 to restart.
If the PSU voltage is correct contact the
VERIPOS Helpdesk.