15 Specifications
3.
Ground the largest possible surface area of the shield to the metal panel.
Yaskawa recommends using cable clamps.
A - Braided shield cable
B - Metal panel
15
Specifications
◆
Specifications
Items
Model
Supported Messages
I/O Assembly Instance
DeviceNet Specification
DeviceNet Profile
Input Power
Connector Type
Physical Layer Type
MAC ID Setting
Communications Speed/Baud Rate
100
Figure 14.4 Option Installation for CE Compliance: FP605
Figure 14.5 Ground Area
Table 15.1 Option Specifications
SI-N3
• Group 2 Server (UCMM capable).
• Explicit Messages: Fragmentation is supported. Up to 32 bytes can be input and output.
• Polled I/O Messages: Fragmentation is not supported. Up to 8 bytes can be input and output.
• Faulted Node Recovery/Offline Connection Set Messages/Automatic Device Replacement (ADR).
• Change of State Message (COS). COS can be used as an I/O Input Assembly.
Input: 21 types (4 - 8 bytes)
Output: 21 types (4 - 8 bytes)
Conformance Level 27: Passed
AC Drive
Power Supply Voltage: 11 Vdc - 25 Vdc
Current: 40 mA
5-pin open-style screw connector
Isolated Physical Layer
CAN transceiver + photocoupler
Programmable from drive keypad or network:
MAC ID: 0 - 63
Programmable from drive keypad or network:
• 125/250/500 kbps
• Auto Baud Rate
• Idle Mode Detect
• Heartbeat
C - Cable clamp (conductive)
Specifications
YASKAWA SIEP C730600 84F DeviceNet Technical Manual