Data loss. To avoid data loss and file system corruption, use graceful shutdown
Caution -
unless it is an emergency.
Using the Oracle ILOM CLI:
a.   
Log in to Oracle ILOM using an ssh client. Type:
$
ssh username@
Where username is a user account name with Reset and Host Control (r) privileges
and sp_ip_address is the IP address of the server node service processor.
When prompted, enter the user account password.
b.   
c.   
Enter the command to shut down the server node:
For a graceful shutdown, type:
->
stop /SYS
The server node shuts down gracefully.
For an emergency shutdown, type:
->
stop -f /SYS
The server node shuts down immediately.
Data loss. To avoid data loss and file system corruption, use graceful shutdown
Caution -
unless it is an emergency.
Power Off the System
The appliance database must be shut down before powering off the system chassis.
Shut down both server nodes.
1.
Shutting down both server nodes places the system in standby power mode.
See
"Shut Down a Server Node" on page
Disconnect the AC power cords from the system.
2.
Disconnecting the power cords from the system removes all power from the system.
sp_ip_address
31.
Chapter 2 • Preparing Oracle Database Appliance for Service
Power Off the System
33