Oracle Database Appliance Service Manual page 118

Table of Contents

Advertisement

Remove Front Indicator Panel
See
b.   
Disconnect the power cords from the system.
c.   
If the system is installed in a rack, remove it.
See the Oracle Database Appliance Owner's Guide for information on racking the system
chassis.
d.   
Attach an antistatic wrist strap.
See
2.
Remove the adjacent disk drives [1].
Be sure to mark them so that you can return them to the correct drive bays later.
Unscrew the three Phillips screws from the back of the ear bezel [2].
3.
Remove four more Phillips screws from the inside of the drive bays [3].
4.
Remove the ear bezel [4].
5.
The ear bezel and indicator panels remain connected to the ribbon cables.
118
Oracle Database Appliance Service Manual • February 2016
"Shutting Down a Server Node and Powering Off the System" on page
"Performing Electrostatic Discharge and Antistatic Prevention Measures" on page
31.
34.

Advertisement

Table of Contents
loading

Table of Contents