Remove Front Indicator Panel
See
b.
Disconnect the power cords from the system.
c.
If the system is installed in a rack, remove it.
See the Oracle Database Appliance Owner's Guide for information on racking the system
chassis.
d.
Attach an antistatic wrist strap.
See
2.
Remove the adjacent disk drives [1].
Be sure to mark them so that you can return them to the correct drive bays later.
Unscrew the three Phillips screws from the back of the ear bezel [2].
3.
Remove four more Phillips screws from the inside of the drive bays [3].
4.
Remove the ear bezel [4].
5.
The ear bezel and indicator panels remain connected to the ribbon cables.
118
Oracle Database Appliance Service Manual • February 2016
"Shutting Down a Server Node and Powering Off the System" on page
"Performing Electrostatic Discharge and Antistatic Prevention Measures" on page
31.
34.