Selecting Output - Fuji Electric ZSVS-2 Instruction Manual

Compact type gas analyzer
Table of Contents

Advertisement

4.3.3 Selecting output

Current output (4 to 20mA DC) or voltage output (0 to 1V DC) can be selected in this mode.
To switch between current and voltage outputs, switch the jumper pin of the control printed board.
Caution on setting
• When making the setting in this mode, be sure to switch the jumper pin of the control printed
board. Otherwise accurate output signal cannot be obtained.
Setting contents
Select "4 to 20mA DC" or "0 to 1V DC."
Jumper switching
Output cannel
CH1
CH2
CH3
CH4
CH5
CH6
CH7
CH8
Jumper
4 to 20mA DC
JP1
1-2
JP2
1-2
JP3
1-2
JP4
1-2
JP5
1-2
JP6
1-2
JP7
1-2
JP8
1-2
JP1 JP2 JP3 JP4 JP5 JP6 JP7
0 to 1V DC
2-3
2-3
2-3
2-3
2-3
2-3
2-3
2-3
1 JP8 3
1 JP8 3
JP8
- 48 -
Initial value
"Depends on specifications."
(4 to 20mA DC)
Between 1 and 2
(0 to 1V DC)
Between 2 and 3
INZ-TN2ZSVS-E