SRX110 Services Gateway Hardware
Related
Documentation
SRX110 Services Gateway Power Specifications and Requirements
68
Table 21: Site Electrical Wiring Guidelines for the Services
Gateway (continued)
Site Wiring Factor
Radio Frequency
Interference (RFI)
Electromagnetic
Compatibility (EMC)
CAUTION:
To comply with intrabuilding lightning/surge requirements, the
intrabuilding wiring must be shielded. The shielding for the wiring must be
grounded at both ends.
General Site Guidelines for Installing the SRX110 Services Gateway on page 38
SRX110 Services Gateway Power Specifications and Requirements on page 68
The AC power system electrical specifications for the SRX110 Services Gateway are listed
in
Table 22 on page
68.
Table 22: Power Supply Electrical Specifications for the SRX110 Services
Gateway
Power Requirement
AC input voltage
AC input line frequency
AC system current rating
Guideline
To reduce or eliminate the emission of RFI from your site wiring:
Use twisted-pair cable with a good distribution of grounding
conductors.
Use a high-quality twisted-pair cable with one ground conductor
for each data signal when applicable, if you must exceed the
recommended distances.
Provide a properly grounded and shielded environment and use
electrical surge-suppression devices.
Strong sources of electromagnetic interference (EMI) can cause
the following damage:
Destroy the signal drivers and receivers in the device
Conduct power surges over the lines into the equipment, resulting
in an electrical hazard
NOTE:
If your site is susceptible to problems with EMC, particularly
from lightning or radio transmitters, you may want to seek expert
advice.
Specification
100 to 240 VAC
50 to 60 Hz
1.5 A maximum
Copyright © 2012, Juniper Networks, Inc.