Piping System Diagram; Assembly Of Receiver Unit And Transmitter Unit - Fuji Electric FE ZSS Instruction Manual

Cross stack laser gas analyzer
Table of Contents

Advertisement

8/6 Teflon tube
(outside product)
Purging gas inlet
(with bell-and-spigot
Receiver box
joint for 8/6)
( 20× 80× 00)
Approx. 400
Angle adjustment
unit
00
Receiver unit
240
Power supply
AO
Cable between control unit and receiver unit (standard : 5m)

4.9 Assembly of receiver unit and transmitter unit

(1) Prepare "Receiver box or transmitter box" and "Hexagonal socket bolt" as shown in the following fig-
ure (Fig. 4 - 11). (When the O-ring is not mounted to the receiver unit or the transmitter unit, mount the
O-ring.)
(2) Mount "Receiver box or transmitter box" on "Angle adjustment unit" so that the cable receptor is posi-
tioned down.
(3) Fix it with the 6 "hexagonal socket bolts".
Receiver box or
transmitter box
Cable receptor

4.8 Piping system diagram

With bolt and nut
(M 6×55)
Companion
flange pipe to
50 to 200
mount stack
(outside product)
Stack
0.5 to 0m
JIS 0K50A FF
(with packing)
30
2- 2
74
Control unit
34
2
DI/O
AI
Hexagonal socket bolt
Copper or SUS pipe (outside product)
Instrumentation air line joint (outside product)
Flow meter
Flow meter
20 to 00L/min
Mist
separator
50 to 200
Approx. 400
Angle adjustment unit
Purge inlet
Transmitter unit
Receiver / Transmitter unit cable (standard : 2m)
Note ) Be sure to mount the R /4 stopper (ZZP*ZSSTK738 4P7)
to the drain outlet of the mist separator.
3
Fig. 4-10
O-ring
Fig. 4-11
- 18 -
Filter regulator
Instrumentation
air inlet
Note )
Transmitter box
( 80×240× 00)
00
ngle adjustment unit
INZ-TN1ZSS-E

Advertisement

Table of Contents
loading

Table of Contents