4.7.1 How to operate the angle adjustment unit

(1) When you tighten the B flange
Turn the fixing bolt and the anchor nut clockwise at the same time.
If it is difficult to turn them, slightly loosen the anchor nut first.
(2) When you loosen the B flange
Turn the fixing bolt and the anchor nut counter-clockwise at the
same time. If it is difficult to turn them, slightly loosen the anchor
nut first.
(3) When you fasten B flange
When angle is determined after adjustment in 1) or 2), turn them in
the direction opposite to each other to fasten them. Be careful be-
cause if the fixing bolt and the anchor nut are too far away from the
B flange, the angle will slip.
Pay attention to the insertion angle of the spanner. Take utmost care
not to turn at the angle which may let the bellows contact with the
head of the spanner. Otherwise, it will smash the bellows.