Measurement Settings; Piping Parameter Setting Method; Key Operations For Measurement Settings - Fuji Electric FSZ Instruction Manual

Integral ultrasonic flowmeter s-flow
Table of Contents

Advertisement

3.8.1. Piping parameter setting method

Description
Sets parameters for piping and measurement fluids.
Be sure to set the following parameters before mounting the flowmeter to a pipe.
Set the accurate pipe outer diameter and wall thickness dimensions. Otherwise, performance can be impaired.
If the exact parameters are not set, there will be large measurement errors.
Wave receipt errors may also occur.
Item
1. Pipe outer diameter
2. Pipe material
3. Pipe thickness
4. Measurement fluids
5. Dynamic viscosity coefficient : (Factory default: 1.004 x 10
6. Flow direction
For specific key operations, refer to the example in

3.8.2. Key operations for measurement settings

Operation (example)
Display and keystrokes
1
Measurement display
Press and hold the ○ key
2
○ Key
3
○ Key
4
○ Key
5
○ Key
6
○ key

3.8. Measurement settings

: 5.00 to 99.99 [mm] (Factory default: FSZ08: 13.80, FSZ15: 21.70, FSZ25: 34.00 [mm])
: Carbon Steel, stainless steel (factory default), copper, PVC, PFA, PTFE
: 0.10 to 9.99 [mm] (factory default: FSZ 08: 2.00, FSZ 15: 2.50, FSZ 25: 3.00 [mm])
: Water (factory default), seawater, fluid sound velocity
Fluid sound velocity: (Sound velocity: 1000 to 2000 [m/s])
: R-L, L-R
R-L: Flow direction from right to left from the front of the flowmeter
L-R: Flow direction from left to right from the front of the flowmeter
3.8.2.
Press and hold the ○ key to go to Display 2.
Press the ▽ key twice and select "SET PIPE".
Press the ○ key to go to Display 3.
Pipe outer diameter: 5.00 to 99.99 [mm]
Press the △▽ keys to set the values.
Press the ○ key to go to Display 4.
Pipe material: Carbon steel, stainless steel, copper,
*For PP or PVDF, select "PVC".
Press the △▽ keys to set the items.
Press the ○ key to go to Display 5.
Pipe thickness: 0.10 to 9.99 [mm]
Press the △▽ keys to set the values.
Press the ○ key to go to Display 6.
Measurement fluids: Water,
Press the △▽ keys to set the items.
Select water or seawater and press the ○ key to go to Display 8.
○ key
Select the fluid sound velocity and press the ○ key to go to Display 7.
- 22 -
-6
[m
2
/s])
Description
,
,
seawater, fluid sound velocity
,
,
PVC,
PFA,
PTFE
,
,
,
(initial values)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fsz08Fsz15Fsz25

Table of Contents