Configuring The Event Types To Be Reported To The Monitoring Station - Visonic PowerMax10-G2 Installer's Manual

Wireless intrusion and fire alarm system
Hide thumbs Also See for PowerMax10-G2:
Table of Contents

Advertisement

The PowerMax10-G2 display will read [broadband]. Here you determine if the
Broadband Module line disconnection will be reported or not and determine the
delay between detection of line disconnection and report failure. If the telephone
line is disconnected, the event "BBA line fail" will be stored in the event log.
97.
Press the
I
OK
The PowerMax10-G2 display will read [ don't report
98.
Press the
" 5 minutes ", " 30 minutes ", " 60 minutes ", " 180 minutes " and " don't
report ", for example, " 30 minutes ".
99.
Press
to confirm the selection.
I
OK
The PowerMax10-G2 display will revert to [broadband].
100.
Press the
The PowerMax10-G2 display will revert to [LINE FAIL REPORT].
You can now press the
(see Configuring Remote Programming Access Permissions), or press the
button to take you to "

4.6.3.8 Configuring the Event Types to be Reported to the Monitoring Station

Continue below from the previous section or repeat steps 1 to 7 of section 4.6.3.1and then press the
button repeatedly until the PowerMax10-G2 display will read [AUTO TEST TIME]
101.
Press the
The PowerMax10-G2 display will read [RPRT CNFRM ALARM]. Here you
determine whether the system will report whenever 2 or more events
(confirmed alarm) occur during a specific period.
102.
Press the
I
OK
The PowerMax10-G2 display will read [disable report].
103.
Press the
" disable report ", " enable + bypass " and " enable report ", for example,
" enable report ".
104.
Press
to confirm the selection.
I
OK
The PowerMax10-G2 display will revert to [RPRT CONFRM ALARM].
105.
Press the
The PowerMax10-G2 display will read [RECENT CLOSE]. Here you enable or
disable the "recent closing" report, that is sent to the Monitoring Station if an alarm
occurs within 2 minutes from the expiry of the exit delay.
106.
When the PowerMax10-G2 display reads [RECENT CLOSE], press the
button.
The PowerMax10-G2 display will read [recent cl. OFF
107.
Press the
"recent cl. ON", for example, "recent cl. ON".
108.
Press
to confirm the selection.
I
OK
The PowerMax10-G2 display will revert to [RECENT CLOSE].
D-302756
button.
or
button repeatedly to select between " 2 minutes ",
button.
button to take you to the "
<OK> TO EXIT
button.
button.
or
button repeatedly to select between
button.
or
button to select between "recent cl. OFF" and
].
PSTN UP/DOWN
".
].
don't report
30 minutes
LINE FAIL REPORT
" menu
RPRT CNFRM ALARM
disable report
enable report
enable report
RPRT CONFRM ALARM
RECENT CLOSE
I
OK
recent cl. OFF
recent cl. ON
rem. access OFF
RECENT CLOSE
broadband
I
OK
or
30 minutes
I
OK
broadband
or
I
OK
or
I
OK
I
OK
or
I
OK
33

Advertisement

Table of Contents
loading

Table of Contents