5. PROGRAMMING
PowerMaster String Editor
Key
String Editor Functionality
Moves the digits cursor from left to right. Long press for fast movement.
Moves the digits cursor from right to left. Long press for fast movement.
Places digits cursor to the extreme right position of edit string and shows the last 16 digits of string.
Scrolls upward the alphanumerical/symbols sequence of inserted digits. Long press for fast scroll.
For the sequence of the digits, see end of this table.
Scrolls downward the alphanumerical/symbols sequence of inserted digits. Long press for fast scroll.
For the sequence of the digits see end of this table.
Changes between lowercase letters (a,b,c...z) and uppercase letters (A,B,C...Z).
Clears a single digit of the string by cursor.
Clears all digits of the string to the right of cursor.
Confirms and saves the edited string and reverts to previous menu.
Exiting the edit screen and moves one level up to previous or top menu without saving the edit string.
Exiting the edit screen and moves to the "<OK> TO EXIT" exit screen without saving the edit string.
Sequence
Alphanumeric/symbol sequence: a/A, b/B....z/Z; 0,1,2...9; ! # % & ' * + - / = ^ @ . _ ?

5.6.4 Configuring Events Reporting to Monitoring Stations

The PowerMaster control panel is designed to report alarm, alerts, troubles and other events and messages to two
Monitoring Stations C.S.1 and C.S.2 via PSTN telephone line, Cellular i.e. GSM voice (analog), GPRS (IP) & SMS or
Broadband IP communications channels. In this section you configure and define all parameters and features required
for the reporting of the event messages to Monitoring Stations such as:
The events reported to each of the two Monitoring Stations C.S.1 and C.S.2 and corresponding backups.
The communication means (channel) used for the reporting and the backup means (channel) in case of failure.
The customer's (subscriber) account number(s) to be reported to each monitoring station.
The telephone numbers, IP addresses and SMS numbers and reporting formats of the corresponding alarm receivers
at the two Monitoring Stations C.S.1 and C.S.2 and the number of reporting retry attempts in case of failure to report.
The communication Auto Tests and communication Fail reports.
The reporting of certain system function events such as "Confirmed Alarm", "Recent Close", Zone Restore" and
"System Not-Used".
Note: The notification of events to other 3rd party applications (SMS/IP/personal phones) is a supplementary
feature that has not been investigated by UL and is not used in UL listed installations.
04:COMMUNICATION
Enter "3:C.S.REPORTING", select the menu you wish to configure (see guidance above and in section 5.6.1), then
refer to the table below which provides you with detailed explanations and configuration instructions for each option.
Option
01:REPORT EVENTS
02:1st RPRT CHAN
03:2nd RPRT CHAN
04:3rd RPRT CHAN
48
⋅ ⋅ ⋅
3:C.S.REPORTING
Configuration Instructions
Define which events (i.e. Alarms (alrm); Open/close (o/c); Alerts (alrt); All events (all);
Maintenance and Troubles) will be reported to the Monitoring Stations.
The minus (-) symbol means "less/except" e.g. all(-alrt) means all events except alerts.
The asterisk ( ) is a separator between events reported to Monitoring Station 1 (C.S.1) and
events reported to Monitoring Station 2 (C.S.2). For detailed and more complete
explanation see the "Event Reporting Chart" at the end of this section.
Options:
all-o/c
backup (default)
all
all
all-o/c all-o/c
Note: Alarm events (alrm) have highest priority and Alert events (alrt) have lowest priority.
If the system is equipped also with Cellular communicators, you must define which of the
communicating channels (i.e. Cellular or PSTN) the system will use as the main channel (i.e.
st
1
priority) for reporting event messages to Monitoring Stations, and if the main channel fails,
which channels will be used for the 2
⋅ ⋅ ⋅
MENU you wish
all-o/c o/c
all(-alrt) alrt
alrm all(-alrm)
nd
rd
and 3
reporting priorities.
D-304762 PowerMaster-10/30 G2 Installer's Guide
disable report
all
backup