Setting User Codes; Enabling User Permit For Installer Access; Configuring Permissions For System Reset After Alarm Event - Visonic PowerMax10-G2 Installer's Manual

Wireless intrusion and fire alarm system
Hide thumbs Also See for PowerMax10-G2:
Table of Contents

Advertisement

The PowerMax10-G2 display reads [
sounds to confirm the new MASTER INSTALLER code.
You can now press the
button to take you to "
Note: Master Installer Code should never be programmed as "0000". Doing so will lock the user out of the installer menu!

4.3.3 Setting User Codes

For detailed instructions on setting user codes, refer to the PowerMax10-G2 user guide "Menus and Functions".

4.3.4 Enabling User Permit for Installer Access

User Permission enables you to determine whether access to the INSTALLER MODE requires user permission. Access to
the installer menu, in PowerMax10-G2 that has "User Permission" enabled (for example, in UK) is via the last menu in the
user menu. This option can be changed, if necessary. Here you determine whether the access to the INSTALLER MODE
requires user permission. If you select ENABLE, the installer mode will be accessible only through the user menu after
entering the user code.
Options: Enable (default in UK), Disable (default).
Note: To comply with EN requirements, "Enable" must be selected.
To Enable User Permit for Installer Access
1.
Make sure the system is disarmed and then press the
repeatedly until the PowerMax10-G2 display reads "INSTALLER MODE".
2.
When the PowerMax10-G2 display reads [INSTALLER MODE], press
The screen will now prompt you to enter your installer code.
3.
Enter your Installer Code.
4.
Press the
option.
5.
When the PowerMax10-G2 display reads [DEFINE PANEL], press
The PowerMax10-G2 display will read [01:ENTRY DELAY 1].
6.
When the PowerMax10-G2 display reads [01:ENTRY DELAY 1], press the
or
PERMIT].
Press
and select between "Disable" (default) and "Enable" and then
7.
I
OK
press
to confirm.
I
OK
The PowerMax10-G2 display reverts to "
☺ sounds.
You can now press the
"
" or press the
DEFINE PANEL

4.3.5 Configuring Permissions for System Reset after Alarm Event

(Not applicable in the USA)
Here you determine whether the system can be rearmed (after an event) by the user or only by the installer.
Options: user reset (default), engineer reset, or anti code reset.
If Engineer Reset is selected, the system can be rearmed only by the installer; by entering and exiting the installer menu, by
entering and exiting the event log (see section 8), or by remote telephone. To perform Engineer Reset via the telephone,
establish communication with the PowerMax10-G2 (see user guide, Chapter 5) and continue as follows:
a.
[*], [installer code], [#]
b. Wait for 2 beeps
c.
[*], [1], [#]
d.
[*], [99], [#]
Visonic uses Technistore anti code reset. Installers should check with their Monitoring Station for a code version (seed
code) which needs to be entered.
10
NEW MASTER CODE
button to set the INSTALLER code or press the
<OK> TO EXIT
or
button repeatedly and select the [DEFINE PANEL]
button repeatedly until the display will read [36:USER
36:USER PERMIT
or
button to take you to "
] and a "Happy Tune"
".
" and a "Happy Tune"
button to program any other menu in
<OK> TO EXIT
button
.
I
OK
I
OK
".
NEW MASTER CODE
READY 00:00
INSTALLER MODE
I
OK
ENTER CODE:
CODE
or
DEFINE PANEL
I
OK
01:ENTRY DELAY 1
or
36:USER PERMIT
I
OK
36:USER PERMIT
D-302756