Dismounting The Control Panel; Replacing The Backup Battery; Fuse Replacement; Replacing/Relocating Detectors - Visonic PowerMax10-G2 Installer's Manual

Wireless intrusion and fire alarm system
Hide thumbs Also See for PowerMax10-G2:
Table of Contents

Advertisement

Fault
COMM. FAILURE
CPU LOW BATTERY
CPU TAMPER
FUSE TROUBLE
LINE FAILURE

7.2 Dismounting the Control Panel

A. Remove the screw that fastens the front unit to the back unit (see Figure 3.3).
B. Remove the 4 screws that fasten the back unit to the mounting surface (see Figure 3.3) and remove the control panel.

7.3 Replacing the Backup Battery

Replacement and first-time insertion of battery pack is similar (see Figure 3.1).
With fresh battery pack, correct insertion and tightened battery compartment lid, the TROUBLE indicator should extinguish.
However, the "MEMORY" message will now blink in the display (caused by the "tamper" alarm you triggered when opening
the battery compartment lid). Clear it by arming the system and immediately disarming.

7.4 Fuse Replacement

The PowerMax10-G2 has an internal fuse that has automatic reset. Therefore, there is no need to replace the fuse.
When over current condition occurs, the fuse cuts off the circuit current. Upon fault current being removed for several
seconds, the fuse is automatically reset and allows current flow through the circuit again.

7.5 Replacing/Relocating Detectors

Whenever maintenance work involves replacement or re-location of detectors, always perform a full diagnostic test
according to section 5.
Remember! A "poor" signal is not acceptable, as stated at the end of the introduction to the test procedure.

7.6 Restore Factory Defaults

If you want to reset the PowerMax10-G2 parameters to the factory default parameters, you should enter the installer menu
and perform the "FACTORY DEFLT" function, as detailed below. To get the relevant parameters defaults, contact the
PowerMax10-G2 dealer.
Note: For PowerMax10-G2 with 2 installer codes, INSTALLER code and MASTER INSTALLER code, only the master
installer code enables to perform factory default function.
To Reset PowerMax10-G2 Parameters to the Factory Default Parameters
1.
Make sure the system is disarmed and then press the
repeatedly until the PowerMax10-G2 display reads "INSTALLER MODE".
2.
When the PowerMax10-G2 display reads [INSTALLER MODE], press
The screen will now prompt you to enter your installer code.
3.
Enter your Installer Code.
The PowerMax10-G2 display will read [NEW INSTL CODE].
4.
When the PowerMax10-G2 display reads [NEW INSTL CODE] press the
or
button repeatedly until the PowerMax10-G2 display will read
[FACTORY DEFLT].
D-302756
What it means
A message could not be sent to the monitoring
station or to a private telephone (or a message
was sent but was not acknowledged)
The backup battery within the control panel is
weak and must be replaced (see Chapter 7 -
Replacing Backup Battery).
The control panel was physically tampered
with or its cover was opened, or it was
removed from wall.
The PGM fuse is burnt out or overloaded.
There is a problem with the telephone line
Solution
i) Check telephone cable connection
ii) Check that correct telephone number has
been dialed.
iii) Dial Monitoring Station to check whether or
not events are received.
i) Check for AC power is available in the
Panel.
ii) If trouble exists for more than 72 hours,
replace the battery pack
The control panel is not closed properly. Open
the control panel and then close it.
Make sure that the connection load conforms
to that specified in the Specifications.
i) Lift the telephone receiver and make sure a
telephone line can be heard
ii) Check the telephone connection to the
control panel
button
.
I
OK
READY 00:00
INSTALLER MODE
I
OK
ENTER CODE:
CODE
NEW INSTL CODE
or
69