Outputs - Datalogic Matrix 300N Series Product Reference Manual

Hide thumbs Also See for Matrix 300N Series:
Table of Contents

Advertisement

OUTPUTS

CAUTION
Three general purpose outputs are available and their meaning can be defined by the
user. They are typically used either to signal the data collection result or to control an
external lighting system.
CBX100/500
+V
O1+
O1-
O2+
O2-
O3A
-V
The electrical features of the outputs are the following:
Outputs 1 and 2
V
CE
I
= 40 mA continuous max.; 130 mA
CE
pulsed max.
V
CE saturation
P
= 90 mW Max. @ 50 °C ambient temp.
D
By default, Output 1 is associated with the No Read event, which activates when the
code(s) signaled by the external trigger are not decoded, and Output 2 is associated
with the Good Read event, which activates when all the selected codes are correctly
decoded.
The output signals are fully programmable being determined by the configured Activa-
tion/Deactivation events, Deactivation Timeout or a combination of the two. Refer to
the DL.CODE parameters Help On Line for further details.
When Outputs 1 and 2 are connected through the CBX connection box,
they become opto-isolated and polarity sensitive and acquire the electri-
cal characteristics listed below. To function correctly, they require setting
the Output Line Type configuration parameters to NPN for the respective
output. The hardware connection to the CBX can be either NPN or PNP.
Description
Power Source - Outputs
Output 1 + opto-isolated and polarity sensitive
Output 1 - opto-isolated and polarity sensitive
Output 2 + opto-isolated and polarity sensitive
Output 2 - opto-isolated and polarity sensitive
Output 3 non opto-isolated (only available on CBX500)
Power Reference - Outputs
= 30 Vdc max.
= 1 Vdc max. @ 10 mA
Output 3
Reverse-Polarity and Short-Circuit Pro-
tected
V
(I
= 0 mA) max = 30 Vdc
OUT
LOAD
V
(I
= 100 mA) max = 3 Vdc
OUT
LOAD
I
max = 100 mA
LOAD
PRODUCT REFERENCE GUIDE
OUTPUTS
79

Advertisement

Table of Contents
loading

Table of Contents