RAPID CONFIGURATION
STEP 4 - X-PRESS CONFIGURATION
Once Matrix 300N is focused at the correct reading distance, you must configure it for
optimal code reading relative to your application.
Aim
1. Enter the Aim function by pressing and hold-
2. Release the button to enter the Aim function.
3. Select a single code from your application.
Setup
4. Enter the Setup function by pressing and
5. Release the button to enter the Setup
6
MATRIX 300N
ing the X-PRESS push button until the Aim LED
is on.
The laser pointers turn on.
Position the code at the center of the FOV
(equidistant from the aiming indicators.
For Liquid Lens models, the reader may start flashing
and try to perform autofocus, however this will have no
effect on the application specific code; it can be ignored.
Exit the Aim function by pressing the X-PRESS
push button once. After a short delay the Aim
function is canceled and the laser pointers
turn off.
holding the X-PRESS push button until
the Setup LED is on.
function. The Setup LED will blink until
the procedure is completed.
The Setup procedure ends when the
Image Acquisition parameters are suc-
cessfully saved in the reader memory, the
Setup LED will stop blinking and Matrix
300N emits 3 high pitched beeps.
If the calibration cannot be reached after
a timeout of about 5 (five) seconds,
Matrix 300N will exit without saving the
parameters to memory, the Setup LED
will stop blinking and in this case Matrix
300N emits a long low pitched beep.
Figure 8 - X-PRESS Interface: Aim
Function
Figure 8 - X-PRESS Interface:
Setup Function