CBX Electrical Connections

Outputs

When Outputs 1 and 2 are connected through the CBX connection box, they become
opto-isolated and polarity sensitive and acquire the electrical characteristics listed
below. To function correctly, they require setting the Output Line Type configuration
parameters to NPN for the respective output. The hardware connection to the CBX
CAUTION
can be either NPN or PNP.
Three general purpose outputs are available and their meaning can be defined
by the user. They are typically used either to signal the data collection result or
to control an external lighting system.
CBX100/500
+V
O1+
O1-
O2+
O2-
-V
The electrical features of the outputs are the following:
64
Figure 45 - NPN Input 2 Using External Power
Power Source - Outputs
Output 1 + opto-isolated and polarity sensitive
Output 1 - opto-isolated and polarity sensitive
Output 2 + opto-isolated and polarity sensitive
Output 2 - opto-isolated and polarity sensitive
Power Reference - Outputs
Outputs 1 and 2
V
= 30 Vdc max.
CE
I
= 40 mA continuous max.; 130 mA pulsed max.
CE
V
= 1 Vdc max. @ 10 mA
CE saturation
P
= 90 mW Max. @ 50 °C ambient temp.