Cbx Electrical Connections - Datalogic Matrix 300N Series Product Reference Manual

Hide thumbs Also See for Matrix 300N Series:
Table of Contents

Advertisement

CHAPTER 4

CBX ELECTRICAL CONNECTIONS

All Matrix 300N Standard Input Power models can be connected to a CBX connection
box through one of the available CAB-DSxx-S accessory cables. These accessory cables
terminate in an M12 17-pin connector on the Matrix 300N side and in a 25-pin male D-
sub connector on the CBX side.
We recommend making system connections through one of the CBX connection boxes
since they offer the advantages of easy connection, easy device replacement, opto-iso-
lated outputs (Outputs 1 and 2), and filtered reference signals.
NOTE
The table below gives the pinout of the CBX100/500 terminal block connectors. Use this
pinout when the Matrix 300N reader is connected by means of the CBX100/500:
Group
Input Power
Inputs
60
MATRIX 300N
If you require direct wiring to the reader the connections are the same as
shown in this chapter with the exception of the digital Outputs. Direct
wiring details are indicated in Appendix A .
Label
Vdc
GND
Earth
+V
I1A
I1B
-V
+V
I2A
I2B
-V
Description
Power Supply Input Voltage +
Power Supply Input Voltage -
Protection Earth Ground
Power Source - External Trigger
External Trigger A (polarity insensitive)
External Trigger B (polarity insensitive)
Power Reference - External Trigger
Power Source - Inputs
Input 2 A (polarity insensitive)
Input 2 B (polarity insensitive)
Power Reference - Inputs

Advertisement

Table of Contents
loading

Table of Contents