INSTALLATION
2.3.5

Outputs

Two general purpose outputs are available. These outputs can only be connected as
open collector configurations. The following pins are present on the connector of the
scanner:
Pin
8
11
10, 12, 22 I/O REF
The meaning of the two outputs OUT1 and OUT2 can be defined by the user (No
Read, Right or Wrong). Refer to the WinHost Help On Line.
By default, OUT1 is associated with the No Read event, which activates when the
code signaled by the External Trigger is not decoded, and OUT2 is associated with
the Right event, which activates when the code is correctly decoded.
DS2200
V
max = 50 Vdc
CE
I max = 50 mA continuous
These outputs are both level or pulse configurable.
2.4

POSITIONING

The DS2200 scanner is able to decode barcode labels at a variety of angles,
however significant angular distortion may degrade reading performance.
When mounting the DS2200 take into consideration these three ideal label position
angles: Pitch 0°, Skew 15° to 30° and Tilt 0°.
Follow the suggestions for the best orientation:
Name
Function
OUT1+
output 1 +
OUT2+
output 2 +
I/O reference
+
8/11
I/O REF
10/12/22
Figure 9 - DS2200 output connections
USER INTERFACE
Vext 50 Vdc max, 50 mA max.
2