RAPID CONFIGURATION
Advanced Setup
Lens)
NOTE
To begin configuration, the reader must be correctly mounted at the correct reading dis-
tance for your application so that its Field of View covers the application reading area.
1. From the Task Area select Open Device Configuration.
2. The Open Device Configuration window opens showing the list of currently saved
3. Click on the Advanced Setup button and press the Play icon.
4. Place the Grade A Barcode Test Chart in the reading area. Once positioned, stop
16
MATRIX 300N
for Software Adjustable Focus Models
For Manual Adjustable Focus models go to page 23 then continue the con-
figuration with the " Reading Phase" on page 30 .
configurations (jobs) saved on the device. For new devices, the only saved job is
the Default configuration. Click OK. The device enters run mode and begins acquir-
ing images.
image acquisition by clicking on the Pause button.
(Liquid