Synchronized Id-Net Network Configurations - Datalogic Matrix 300N Series Product Reference Manual

Hide thumbs Also See for Matrix 300N Series:
Table of Contents

Advertisement

Synchronized ID-NET Network Configurations

The Synchronized ID-NET network communications between Master and Slave are inter-
nally managed by the application software. A pre-configured job is loaded with the Syn-
chronized Layout Type and the correct Operating Mode for both the Master and Slaves
when either the Phase Mode or PackTrack Configuration is selected from the Internal
Network Setting feature.
1. Complete the configuration of all the application parameters (including Image Set-
2. Connect to each Slave reader via Ethernet (see note below), and set the Slave spe-
NOTE
tings) and save them to the Master with an application relative name and with the
option to Clone Master configuration on Slaves.
Figure 96
Saving Synchronized Phase Mode Configuration to Master
-
cific parameters.
If necessary, Slave device photometric (Image Settings) parameters must
be configured separately through DL.CODE. This is preferably done
through each device's Ethernet TCP/IP channel. If Slave devices are not
connected to Ethernet you must temporarily (manually) connect them one
by one to perform Image Settings.
INTERNAL NETWORK CONFIGURATIONS
PRODUCT REFERENCE GUIDE
163

Advertisement

Table of Contents
loading

Table of Contents