Outputs - Datalogic DS2200 Installation Manua

Hide thumbs Also See for DS2200:
Table of Contents

Advertisement

DATALOGIC
An anti-disturbance hardware filter is implemented on the External Trigger
input (<5 milliseconds delay).
An additional 15 ms (typical) delay can be implemented through a dedicated
software parameter (refer to WinHost Help On Line).

2.3.5 Outputs

The following pins are present on the connector of the scanner:
Pin
8
10
11
12
The meaning of the two outputs OUT1 and OUT2 can be defined by the user
(No Read, Right or Wrong). Refer to the Winhost Help On Line.
By default, OUT1 is associated with the No Read event, which activates
when the code signalled by the External Trigger is not decoded, and OUT2 is
associated with the Right event, which activates when the code is correctly
decoded.
DS2200
These outputs are both level or pulse configurable.
Name
Function
OUT1+
Output 1 +
I/O REF
I/O Reference
OUT2+
Output 2 +
I/O REF
I/O Reference
OUT1+
8/11
OUT2+
10/12
I/O REF
Figure 2.9 - DS2200 output connections
USER INTERFACE
Vext 50 Vdc max, 50 mA max.
DS2200
Installation - 9