Reset Reader to Factory Default Environment (Optional)

If it ever becomes necessary to reset the reader's Environment parameters to their fac-
tory default values, you can perform this procedure by holding the X-PRESS push button
pressed while powering up the reader. You must keep the X-PRESS push button pressed
until all LEDs blink simultaneously for about 3 seconds. Release and re-press the but-
ton during this LED blinking sequence.
All the device Environment parameters are reset including the default IP Address. The
Matrix 300N emits 3 high pitched beeps and after a few seconds enters run mode.
Any previously saved configurations on the device will remain in memory, but the
Default configuration is set as the startup configuration.
NOTE
8
MATRIX 300N
If you release the button while the LEDs are all on continuously (after the
blinking phase), the reader will enter the Loader program sequence and
the LEDs will begin to cycle through various patterns. Just cycle power to
return to run mode.